Calculators
Ventilation calculators
A tight house needs ventilation designed in, not left to leaks. These calculators give the whole-dwelling mechanical rate, the local exhaust for baths and kitchens, and the air change numbers a blower door test or a room volume produces.
Each page names the standard or code section it works from. The range hood calculator also flags the 400 CFM threshold where makeup air comes into question.
Maintained by BuildSolver · Updated
Which one you need
- Continuous ventilation rate for a house: ASHRAE 62.2 Ventilation Calculator
- Fan size for a bathroom by area or fixtures: Bathroom Exhaust Fan Calculator
- Range hood CFM and makeup air: Range Hood CFM Calculator
- ACH50 from a blower door test: Air Changes per Hour Calculator
Every tool in this section
Ventilation
ASHRAE 62.2 Ventilation Calculator
Whole-dwelling mechanical ventilation rate from floor area and bedroom count.
Applies Qtot = 0.03 x floor area + 7.5 x (bedrooms + 1). The page text explains the IRC M1505.4.3 formula with its smaller 0.01 coefficient, which the calculator does not compute.
Based on ANSI/ASHRAE Standard 62.2
Local exhaust
Bathroom Exhaust Fan Calculator
Bath fan CFM by floor area or by fixture count, rounded up to a standard fan size.
Scales the area method for ceilings above 8 ft and keeps the 50 CFM code minimum as its own check.
Based on HVI guidance, IRC M1505.4.4
Ventilation
Air Changes per Hour Calculator
ACH from CFM and room volume, CFM for a target ACH, and ACH50 from a blower door test.
Checks ACH50 against the IECC limit for the climate zone and edition you pick. The natural infiltration estimate is shown as a rough figure.
Based on IECC 2021 and 2024 air leakage limits
Local exhaust
Range Hood CFM Calculator
Kitchen hood CFM by cooktop width and hood position, checked against the code minimum.
Flags makeup air above 400 CFM when a fuel-burning appliance is inside the air barrier. The gas BTU rule of thumb is shown for reference only.
Based on HVI guidance, IRC M1505.4.4 and M1503.6
Ventilation
Mixed Air Calculator
Two airstreams mixed, economizer fraction.
Mixes outdoor air and return air by the mass of dry air into the mixed dry-bulb, with humidity ratio, enthalpy, RH, wet-bulb and a fog check, next to the plain CFM average. Or percent outdoor air from the outdoor, return and mixed air temperatures, refused when outdoor and return are too close. Runs in the browser with no daily limit.
Based on ASHRAE Fundamentals adiabatic mixing
Ventilation
Outdoor Air Load Calculator
Outdoor air load.
Takes the outdoor air CFM, outdoor dry-bulb with a wet-bulb or RH, the room dry-bulb and RH and the elevation, and returns the sensible, latent and total load in BTU/h and tons for summer cooling or winter heating. Credits are named in words. Shows the 1.08 and 4840 field formulas beside the exact enthalpy figure. Runs in the browser with no daily limit.
Based on ASHRAE Fundamentals
Ventilation
Commercial Kitchen Hood CFM Calculator
Commercial kitchen hood exhaust CFM.
Multiplies the unlisted hood table rate in CFM per foot for the hood style and the heaviest cooking duty under it by the hood length. Takes a listed rate from the hood label and shows the table beside it. Gives makeup air about equal to the exhaust and the grease duct area at 500 to 2,500 fpm. Refuses styles the table does not permit. Type I hoods only. Runs in the browser with no daily limit.
Based on International Mechanical Code
Ventilation
Makeup Air Unit Size Calculator
Exhaust makeup airflow, unit size, heating load, gas input.
Takes the exhaust CFM and the share the unit covers, then returns the makeup CFM and the heat to lift it from the winter design temperature to the supply temperature at 1.08 times CFM times the rise, in BTU/h and kW. Adds burner input at the data sheet efficiency, gas flow in cubic feet per hour and a check of the supply against the room (2015 IMC 508.1.1, 10 F). Heating only, no unit model. Runs in the browser with no daily limit.
Based on International Mechanical Code
Ventilation
ERV and HRV Effectiveness Calculator
Sensible, latent and total effectiveness of an ERV or HRV, or the supply air from a rating.
Divides the change in the supply air by the outdoor to return difference for temperature, humidity ratio and both, as AHRI 1060 defines it, or runs a rated effectiveness forward to the supply temperature and RH. Gives the sensible and latent load moved, the exhaust leaving temperature and the net outdoor air from the EATR. Frost control, fan heat and the HVI sensible recovery efficiency are not covered.
Based on AHRI Standard 1060 (effectiveness, Equations C1 and C2)
Other calculators
Every calculator here lists the standard it works from and what it leaves out. The numbers are for sales-phase sizing and field checks, not a permit submittal. Methodology lists the standard behind each one.