Wheelchair ramp length calculator
Enter the total rise and a slope, and this page gives the number of ramp runs, the horizontal run, the length with the landings and the sloped length, with the requirements of the rule you chose. At the ADA maximum slope of 1:12 a 30 in rise needs 360.0 in of run, 30 ft, which is one run. A 36 in rise is 2 runs with a 60 in landing between them, 41 ft in all. For a poured ramp or its landings use the concrete calculator; for the stair beside it, the stair stringer calculator.
- The vertical height the ramp climbs, in inches, from the surface at its foot to the finished surface it reaches. Under the ADA one run may rise 30 in at most.
- Pick the ADA basis for an accessible route or the IRC basis for a home, and enter the slope as inches of run per inch of rise: 12 for 1:12, or 16 or 20 for a gentler ramp.
- The result gives the number of runs, the horizontal run, the length with the 60 in landings between runs, the sloped length and the slope in percent and degrees.
- The rows below the numbers list the handrail, landing, width and edge protection items of the rule you chose, with the section numbers to confirm on the plans.
Example result for the default inputs
Total rise 30 in, slope 1:12, ADA 2010 Standards, section 405 (public and commercial, new work).
Ramp runs
1 run
Horizontal run
30.0 ft
Length
30.0 ft
Sloped length
30.1 ft
| Slope basis | ADA 2010 Standards, section 405 (public and commercial, new work) |
|---|---|
| Slope | 1:12 = 8.33 percent, 4.8 degrees from horizontal |
| Runs, 405.6 | 30 / 30 = 1.00, rounded up to 1; 30.00 in of rise per run if split equally (30 in maximum per run) |
| Horizontal run | 30 x 12 = 360.0 in (30 ft) |
| Intermediate landings, 405.7 | None: one run. Landings are still needed at its top and bottom. |
| Run plus intermediate landings | 360.0 in (30 ft) |
| Footprint with top and bottom landings | 360.0 + 2 x 60 = 480.0 in (40 ft), at 60 in each minimum (405.7.3); a landing where the ramp turns is 60 by 60 in minimum (405.7.4) |
| Sloped length | sqrt(30^2 + 360.0^2) = 361.2 in (30 ft 1 in), the walking surface of the ramp itself |
| Slope limit, 405.2 | 1:12 is within the 1:12 maximum of 405.2 |
| Handrails, 405.8 and 505 | Required on both sides: 30.00 in of rise per run is greater than 6 in. Top of the gripping surface 34 to 38 in above the ramp, continuous along each run, 12 in horizontal extension beyond the top and bottom |
| Edge protection, 405.9 | On each side of every run and landing: a surface extended 12 in past the handrail, or a curb or barrier that stops a 4 in sphere. Exceptions exist and are not worked here |
| Width and cross slope, 405.5 and 405.3 | 36 in clear width minimum, measured between the handrails where there are any; cross slope 1:48 maximum |
- The Access Board guide recommends a running slope of 7.5 percent at most for exterior ramps (about 1:13.3), so that construction tolerances do not push the built slope past 1:12. This layout is 8.33 percent, which leaves less margin than that.
- Measure the rise from the surface at the foot of the ramp to the surface it climbs to, finished floor to finished floor. A change of a threshold or a step at either end changes the rise.
- This is a layout only, with no structure (loads, framing, decking, footings), no surface or slip resistance, no door clearances and no curb ramps. The adopted code and the authority having jurisdiction decide.
For estimation purposes only. Consult a licensed engineer for final designs.
Sign up with your email. Back on this page in the same browser, your inputs are filled in. No card.
Free without signup
How the ramp length is found
The page works from the rise and the slope. The slope sets how many inches of run each inch of rise needs, the rise is cut into runs of at most 30 in with a 60 in landing between them, and the lengths follow from those. It then lists the requirements of the rule you chose: the ADA Standards, section 405, or the International Residential Code, R311.8.
- Horizontal run
run = total rise x N, for a slope of 1:N30 x 12 = 360.0 in, or 30 ft. Each inch of rise needs 12 in of run at 1:12, so 30 in of rise needs 30 ft. At 1:16 the same rise needs 480.0 in and at 1:20 it needs 600.0 in.- Number of runs
runs = ceil(total rise / 30 in)ADA 405.6 limits the rise of a run to 30 in. 36 / 30 = 1.20, rounded up to 2; 30 in is one run and 61 in is 3. The rise is split equally, 18.00 in per run for 36 in.- Intermediate landings
landings = runs - 1, each 60 in longADA 405.7.3 asks for a landing clear length of 60 in. 36 in of rise has 1 landing between its 2 runs, so the run of 432.0 in grows to 492.0 in, or 41 ft.- Footprint with top and bottom landings
footprint = run + landings + 2 x 60 inLandings are also needed at the top and the bottom of each run (405.7). With them the 36 in ramp covers 612.0 in, 51 ft, along its length.- Sloped length
L = sqrt(total rise^2 + run^2)sqrt(30^2 + 360.0^2) = 361.2 in, or 30 ft 1 in: the length of the walking surface along the slope, a little longer than the run.- Slope in percent and degrees
percent = 100 / N, angle = atan(1 / N)1:12 is 8.33 percent and 4.8 degrees. The Access Board guide gives 8.33 percent for 1:12 and recommends 7.5 percent at most for an exterior ramp, to leave room for construction tolerances.
Six rises at 1:12
Each row is one ADA ramp at a 1:12 slope, worked with the same function as the form. A 6 in rise takes 72.0 in of run and no handrail, and a 60 in rise takes 2 runs and 65 ft with the landings between them.
| Total rise | Slope | Runs | Run, in | Run plus landings, in | Sloped length, in | Handrails |
|---|---|---|---|---|---|---|
| 6 in | 1:12 | 1 | 72.0 | 72.0 | 72.2 | Not required |
| 12 in | 1:12 | 1 | 144.0 | 144.0 | 144.5 | Both sides |
| 24 in | 1:12 | 1 | 288.0 | 288.0 | 289.0 | Both sides |
| 30 in | 1:12 | 1 | 360.0 | 360.0 | 361.2 | Both sides |
| 36 in | 1:12 | 2 | 432.0 | 492.0 | 433.5 | Both sides |
| 60 in | 1:12 | 2 | 720.0 | 780.0 | 722.5 | Both sides |
The sloped length is the diagonal, a little longer than the run: for the 30 in ramp it is 361.2 in against 360.0 in of run. The run is what the site has to hold, and the sloped length is the walking surface and the decking.
Standards and data sources
- 2010 ADA Standards for Accessible Design, section 405 Ramps and section 505 Handrails, on the U.S. Access Board site - The rules behind the ADA bases: running slope not steeper than 1:12 (405.2), the 405.2 Exception and Table 405.2 for existing buildings (1:10 with 6 in of rise, 1:8 with 3 in, steeper than 1:8 prohibited), cross slope 1:48 (405.3), clear width 36 in (405.5), rise 30 in per run (405.6), landings 60 in long and 60 by 60 in where the ramp turns (405.7), handrails above 6 in of rise (405.8), edge protection (405.9) and handrails on both sides, 34 to 38 in high, extended 12 in (505).
- U.S. Access Board, Guide to the ADA Standards, Chapter 4 Ramps and Curb Ramps - The Access Board's reading of section 405: 1:12 is 8.33 percent, the recommended 7.5 percent design slope for exterior ramps, 30 in of rise per run with no limit on the number of runs, and ramps required for a level change greater than 1/2 in. The guide has no table of rise against run, so the lengths on this page are the slope arithmetic.
- IRC 2015, R311.8 Ramps, as printed by Clinton City, Utah, Community Development - The residential text behind the IRC bases: R311.8.1 slope 1:12 for a ramp serving the egress door and 1:8 for all other ramps, with an exception to 1:8 where 1:12 is technically infeasible because of site constraints; R311.8.2 landings 36 in wide; R311.8.3 handrails on at least one side of a ramp steeper than 1:12, 34 to 38 in high. The ICC pages do not open for automated readers, so this is a building department reprint of the 2015 edition.
- Ypsilanti Township, Michigan, Building Department, ramps (2015 Michigan Building Code, R311) - A second reading of the same R311.8 wording: the 1:12 egress ramp, the 1:8 limit for other ramps and the infeasible-site exception, the 36 in landing width and the handrail rule.
- InspectApedia, building access ramp slope and run lengths - A secondary page for the pairing of rise and run at 1:12: a 12 in rise over a 144 in run, and a 30 in rise with a 30 ft run. It cites the older ADAAG 4.8.2, so it is used for the arithmetic only.
Limitations of this calculator
- This page lays out a ramp from its rise and slope and lists the requirements of the rule you pick. It is a planning aid for a quote or a first plan, not a design. The edition adopted and the amendments of your jurisdiction decide, and the building department or the accessibility reviewer decides whether a given case qualifies. Check with them before you build.
- The ADA bases follow the 2010 ADA Standards, section 405. They are written for accessible routes in public and commercial buildings. Which of the bases applies to your building is for the building department to say; a house is normally built under the residential code, which is what the IRC bases follow.
- The 2010 Standards limit the rise of each run to 30 in and the landing length to 60 in. No maximum run length was found in the 2010 text, and the older limits of 30 ft and 40 ft belong to the 1991 guidelines, so they are not applied. The rise is split into equal runs; the total run does not depend on the split, but the handrail test on a rise greater than 6 in applies to each run as built, and the page tests the equal split.
- The existing-building basis applies the 405.2 Exception and Table 405.2 to the whole rise, as one run, which is the cautious reading. It is allowed only where space limits require a steeper slope in an existing site, building or facility, and the jurisdiction decides whether that holds. Other conditions for existing buildings, including the alterations rules of section 202, are not worked here.
- The IRC bases use the 2015 text of R311.8, read in building department reprints. The 2018, 2021 and 2024 editions were not read directly, and local amendments change the section in places. The text read gives no ramp width, no rise limit per run and no landing length, so the IRC result is one run with a 36 in landing width, and the page does not invent the rest.
- This page does not cover structure (loads, framing, decking, footings and guards), surface and slip resistance, door clearances at a landing, curb ramps under section 406, the exceptions to edge protection in 405.9, the grip size of handrails in 505, aisle ramps in assembly areas and the geometry of a switchback beyond the 60 in landings. The width, handrail and edge protection items are listed from the code, not designed.
- Values outside the field ranges are not accepted: rise 0 to 1,000 in and slope 1:1 to 1:48. A rise under 1/2 in is refused, because the guide puts the ramp threshold at a level change greater than 1/2 in. A rise over 120 in is refused, and that cap is this page's own, not the ADA's. A slope gentler than 1:20 computes, with a note that the guide treats it as a walking surface.
- Measure the rise on site, from the finished surface at the foot of the ramp to the finished surface it reaches. One inch of rise at 1:12 is 12 in of run, so a measuring error of an inch moves the foot of the ramp by a foot.
Common mistakes when planning a wheelchair ramp
- Leaving the landings out of the length. A rise of 36 in at 1:12 has a run of 432.0 in, but it is 2 runs, and ADA 405.7 puts a landing of 60 in between them. The run plus the landing is 492.0 in, 41 ft, and with the top and bottom landings it is 612.0 in, 51 ft.
- Rounding the number of runs down. 36 / 30 = 1.20. Rounding down gives 1 run of 36 in, over the 30 in limit of 405.6. Round up: 2 runs. 60 in is exactly 2 runs, and 61 in is 3.
- Reading 1:12 as 12 percent. 1:12 is 8.33 percent. A 12 percent slope is 100 / 12 = 8.33 in of run per inch of rise, which is steeper than 1:12 and is refused on the ADA basis. Enter the slope as inches of run per inch of rise.
- Using the residential 1:8 on a public ramp. IRC R311.8.1 allows 1:8 for ramps other than the egress ramp, 192.0 in of run for 24 in of rise against 288.0 in at 1:12. The ADA says "A slope steeper than 1:8 is prohibited" and allows 1:8 only in existing buildings, for 3 in of rise at most. A 24 in rise at 1:8 is not allowed on either ADA basis.
- Missing the handrail by a hair. 405.8 asks for handrails on a run with a rise greater than 6 in. A 6 in rise needs none, with a run of 72.0 in. At 6.01 in both sides need one, and at 12 in the run is 144.0 in with handrails on both sides, extended 12 in past the top and bottom and set 34 to 38 in above the ramp.
- Measuring the rise a little high. Each inch of rise costs 12 in of run at 1:12. A rise measured as 31 in instead of 30 in turns 360.0 in of run into 372.0 in and, being over 30 in, adds a second run and a landing: 432.0 in. Measure the finished surfaces, thresholds included.
Common questions about wheelchair ramps
How long does a wheelchair ramp need to be?
At the ADA maximum slope of 1:12, a ramp needs 12 in of run for each inch of rise, so 1 ft of run per inch. A rise of 30 in needs 360.0 in, 30 ft; 24 in needs 288.0 in, 24 ft; 12 in needs 144.0 in. A gentler slope is longer: 30 in at 1:16 is 480.0 in and at 1:20 it is 600.0 in. A rise over 30 in adds landings to the length.
What is the maximum slope of an ADA ramp?
Section 405.2 of the 2010 ADA Standards says ramp runs shall have a running slope not steeper than 1:12. That is 8.33 percent, or 4.8 degrees. The Access Board guide recommends 7.5 percent at most for an exterior ramp, which leaves room for construction tolerances. Cross slope may not be steeper than 1:48.
How much can a ramp rise before it needs a landing?
The rise of any ramp run is 30 in at most (405.6), and the number of runs is not limited. Landings go at the top and bottom of each run. A rise of 36 in is 2 runs, with one landing between them: 432.0 in of run plus 60 in is 492.0 in, 41 ft. A rise of 60 in is 2 runs and 120 in is 4 runs.
How big does a ramp landing have to be?
The landing clear length is 60 in at least (405.7.3), and its clear width is at least as wide as the widest ramp run leading to it (405.7.2). Where a ramp changes direction between runs the landing is 60 in by 60 in clear at least (405.7.4). The slope of a landing may not be steeper than 1:48, and a landing in wet conditions has to be designed to shed water.
When does a ramp need handrails?
Under the ADA, a ramp run with a rise greater than 6 in needs handrails, on both sides, 34 to 38 in above the ramp surface and continuous along the run, with a 12 in horizontal extension past the top and bottom of each run. A rise of 6 in needs none and 6.01 in does. Under the 2015 IRC, R311.8.3 asks for a handrail on at least one side of a ramp steeper than 1:12, so a 1:12 residential ramp needs none by that section.
Can a ramp be steeper than 1:12?
Under the ADA only in an existing site, building or facility, where space limits require it, and within Table 405.2: a slope steeper than 1:12 but not steeper than 1:10 for a rise of 6 in at most, and steeper than 1:10 but not steeper than 1:8 for a rise of 3 in at most. A slope steeper than 1:8 is prohibited. At 1:10 a 6 in rise has 60.0 in of run, and at 1:8 a 3 in rise has 24.0 in.
What slope does the residential code allow?
In the 2015 IRC, R311.8.1 sets 1:12 for a ramp serving the required egress door and 1:8 for all other ramps, with an exception to 1:8 where 1:12 is technically infeasible because of site constraints. A 24 in rise needs 288.0 in of run at 1:12 and 192.0 in at 1:8. Later editions and local amendments can differ, so check the one in force where you build.
How wide does a ramp have to be?
Under the ADA the clear width of a ramp run is 36 in at least (405.5), measured between the handrails where there are any. The 2015 IRC text read for this page gives a landing width of 36 in (R311.8.2) but no ramp width, so confirm the width with the building department for a residential ramp.