Preliminary sizing for planning and for checking a quote. The installer, the water heater maker's literature and the local authority having jurisdiction decide the final selection and the installation.

Maintained by BuildSolver · Updated

Calculator · Water heating

Water heater size calculator

A tank-style water heater is sized by its first hour rating, the gallons of hot water it can supply in an hour that starts with a full tank. DOE's worksheet gives the number to match. Count the hot water uses in your busiest single hour, multiply each by DOE's average gallons, and add. The DOE example of 3 showers, 1 shave and 1 round of hand dishwashing comes to 65 gal, so it needs a rating of 65 gal or more. DOE's page prints 66 gallons for this example. Its own line items add to 65 (3 x 20 + 2 + 3), and this page adds the line items. A heat pump water heater with a tank is sized the same way. This page does not size a tankless unit, which the tankless water heater size calculator works from flow and temperature rise, and it does not turn the rating into a tank size.

  1. Enter how many showers, shaves, rounds of hand dishwashing or food prep, dishwasher loads and clothes washer loads can land in the same hour. Pick the time of day with the highest use.
  2. The page uses DOE's average for a shower. If you know the hot water your own shower uses, enter it and only the shower line changes.
  3. The result is the peak hour demand and the first hour rating to look for, which is that many gallons or more. Enter the rating from a model's EnergyGuide label to see whether it covers the demand.

Tank-style and heat pump (with tank) water heaters, sized by first hour rating from DOE's peak hour worksheet. The sample is DOE's worksheet example. The installer and the maker's literature decide the final selection.

DOE uses 20 gallons for each shower. Count the showers that start in the busiest hour.

DOE uses 2 gallons for each shave.

DOE uses 3 gallons for each round, at 2 gallons per minute.

DOE uses 7 gallons for each automatic dishwasher load.

DOE uses 25 gallons for each top-loader load.

DOE uses 15 gallons for each front-loader (H-axis) load.

Blank uses DOE's 20. Enter your own figure if you know it, for example from a low-flow showerhead and your shower time. Only the shower line changes.

From the top left of the EnergyGuide label, or from the maker's literature. A heat pump water heater may not carry the label. Blank skips the check.

Example result for the default inputs

Peak hour with 3 showers, 1 shave, 1 round of hand dishwashing or food prep.

Peak hour demand

65 gal

Minimum first hour rating

65 gal or more

Test draw pattern at that rating (Table I)

Medium-Usage

Calculation details
Showers3 x 20 gal = 60 gal
Shaves1 x 2 gal = 2 gal
Hand dishwashing or food prep1 x 3 gal = 3 gal
Peak hour demand65 gal
Minimum first hour rating65 gal or more
Draw pattern for a rating at the demandMedium-Usage
  • The gallons per use are DOE's averages from a variety of published information, and the worksheet does not estimate daily use. Enter your own gallons per shower if you know them. Count the uses that can land in the same hour, not the whole day.
  • A first hour rating is measured with 58°F supply water and 125°F delivered water (10 CFR 430 Appendix E, 2.3 and 2.4). Colder supply water, or hot water needed hotter than 125°F at the tap, gives less hot water in the hour than the label rating.

For estimation purposes only. Consult a licensed engineer for final designs.

Get this result as a PDF, free account

Sign up with your email. Back on this page in the same browser, your inputs are filled in. No card.

How the demand and the rating to look for are worked

A storage water heater is sized by its first hour rating, the gallons of hot water it can supply in an hour that starts with a full tank of hot water. DOE's worksheet gives the demand to match it against. Count the hot water uses in the busiest single hour of the home, multiply each by DOE's average gallons for that use, and add. The rating of the heater should be at least that many gallons.

Gallons per use
gallons = uses x average gallons per useDOE's worksheet lists 20 gallons for a shower, 2 for a shave, 3 for hand dishwashing or food prep and 7 for an automatic dishwasher load. A clothes washer load is 25 gallons in a top-loader and 15 in a front-loader (H-axis). DOE calls these estimates based on averages from a variety of published information. Enter your own gallons per shower if you know them.
Peak hour demand
demand = sum of (uses x gallons per use)DOE's example has 3 showers, 1 shave and 1 round of hand dishwashing in the busiest hour. That is 60 + 2 + 3 = 65 gal. DOE's page prints 66 gallons for this example. Its own line items add to 65 (3 x 20 + 2 + 3), and this page adds the line items.
Minimum first hour rating
first hour rating >= demandDOE says to look for a model with a first hour rating of the demand or more. For the example the line items give 65 gallons or more, where DOE's page prints 66. A rating above the demand leaves room, and a rating below it is short.
First hour rating
gallons per hour, starting with a full tankDOE defines it as the gallons of hot water the heater can supply per hour, starting with a tank full of hot water. It depends on the tank capacity, the source of heat (burner or element) and the size of the burner or element. 10 CFR 430 Appendix E calls it an estimate of the maximum volume of hot water a non-flow activated water heater can supply within an hour that begins fully heated.
Where the rating is printed
EnergyGuide label, top left cornerThe label lists it as "Capacity (first hour rating)". DOE says the Federal Trade Commission requires that label on new conventional storage water heaters but not on heat pump water heaters. Product literature from the maker may also give the rating. Look there first.
Test conditions
supply 58°F, delivery 125°F10 CFR 430 Appendix E holds the supply water at 58°F ± 2°F (section 2.3) and sets delivery at 125°F ± 5°F (section 2.4). A home with colder supply water, or one that needs water hotter than 125°F at the tap, gets less hot water in the hour than the label rating. Your house may differ.
Test draw pattern
bin from Appendix E, Table I, by first hour ratingSection 5.4.1, Table I picks the draw pattern for the 24-hour test from the rating. In that table, under 18 gallons is Very-Small-Usage, 18 up to under 51 gallons is Low-Usage, 51 up to under 75 gallons is Medium-Usage, 75 gallons or more is High-Usage. The example's 65 gallons falls in Medium-Usage. That bin describes the test and is not a size recommendation. It is a label for the test.
Model check
covers it if rating >= demand, otherwise short by demand - ratingWith a model's rating entered, 66 gal against the example's 65 gal covers it with 1 gal to spare, and 63 gal is short by 2 gal. UF/IFAS EDIS suggests a rating that matches within 1 to 2 gallons of the peak-hour demand. This page flags a model that close and still reports it short, since DOE's rule is the demand or more. Close is not enough.

Seven cases through the same formula

The first row is DOE's worksheet example, and the page gives 65 gal, where DOE prints 66. Rows four and five are the same busy morning with a front-loader and with a top-loader, 69 gal and 79 gal. The last row applies a shower of 15 gal to the DOE example and drops it to 50 gal. That shower figure is an example chosen for this page, and the other rows use DOE's gallons.

Peak hour demand and the test draw pattern bin for seven water heater sizing cases
CasePeak hour demand, galDraw pattern at that rating
DOE worksheet example, 3 showers, 1 shave and 1 hand dishwashing65Medium-Usage
One person, 1 shower and 1 shave22Low-Usage
Two showers, 1 shave and 1 dishwasher load49Low-Usage
Family morning with a front-loader, 2 showers, 2 shaves, 1 hand dishwashing, 1 dishwasher load and 1 front-loader load69Medium-Usage
The same morning with a top-loader load in place of the front-loader79High-Usage
Four showers back to back and 1 front-loader load95High-Usage
DOE example with 15 gallon showers (an example chosen for this page)50Low-Usage

The demand is also the lowest rating to look for. A model rated at the demand or above covers it, and one below is short, even by a gallon. UF/IFAS suggests a rating within 1 to 2 gallons of the demand, so the page notes a model that close and still reports it short.

DOE worksheet used by the form

Average gallons of hot water per use as DOE lists them in the archived copy of its page from July 2, 2026. DOE says they are estimates based on averages from a variety of published information. Treat them as typical. Change them if yours differ.

DOE average gallons of hot water per use
UseGallons per use
Shower20
Shaving (.05 gallon per minute)2
Hand dishwashing or food prep (2 gallons per minute)3
Automatic dishwasher7
Clothes washer, Top-loader25
Clothes washer, H-Axis15

Draw pattern by first hour rating

Table I in section 5.4.1 of 10 CFR 430 Subpart B Appendix E picks the draw pattern for the 24-hour test from the first-hour rating. The bin describes the test, and it is not a size recommendation.

Draw pattern of the 24-hour test by first hour rating
First hour rating at least, galand under, galDraw pattern
018Very-Small-Usage
1851Low-Usage
5175Medium-Usage
75no limitHigh-Usage

Standards and data sources

Limitations of this calculator

  • This page gives a preliminary rating to shop for. The installer, the water heater maker's literature and the local authority having jurisdiction decide the final selection and the installation.
  • The gallons per use are DOE's. DOE says they are estimates based on averages from a variety of information published on websites. A home with longer showers or a different dishwasher will differ, so enter your own gallons per shower when you know them. The other uses use DOE's figures as they are.
  • The count is yours. This page cannot know how many showers start in your busiest hour, and DOE leaves that to you. Pick the time of day with the highest use, and keep the number of people in the home in mind. A count that is too low gives a rating that is too low.
  • The worksheet covers one hour only. DOE notes that it does not estimate total daily hot water use, and this page does not either.
  • A first hour rating is measured at 58°F supply water and 125°F delivered water (10 CFR 430 Appendix E, 2.3 and 2.4). Colder supply water, or water needed hotter than 125°F at the tap, gives less hot water in the hour than the label rating. The page does not adjust the rating for either.
  • The page does not turn a rating into a tank size. DOE says the rating depends on the tank capacity, the source of heat and the size of the burner or element, so two models with the same tank can carry different ratings. Compare the rating on the label.
  • Tank-style heaters only. A tankless or demand-type heater has no first hour rating and is sized by flow and temperature rise, which the tankless water heater size calculator works.
  • Combination space and water heating systems and solar water heating systems are not covered. Their makers or installers size them. DOE notes that solar contractors use worksheets and computer programs for that job.
  • A heat pump water heater with a tank is sized by the same rating, as DOE's page says. The EnergyGuide label is not required on heat pump water heaters, so take the rating from the maker's literature.
  • Counts are accepted from 0 to 20 for each use. A demand over 200 gal gets a warning, because the sources here work household examples of tens of gallons and do not cover a load that large.

Common mistakes when sizing a water heater

  1. Shopping by tank gallons. A bigger tank does not always mean a higher first hour rating. DOE says the rating depends on the tank capacity, the source of heat and the size of the burner or element. Read the rating on the EnergyGuide label, and compare it with the demand, which is 65 gal by the line items of DOE's example.
  2. Counting the whole day. The demand is for the busiest single hour. DOE's example is 3 showers, 1 shave and 1 round of hand dishwashing, 65 gal by its line items. Adding every use from morning to night would give a larger number that no hour needs, and the worksheet does not estimate daily use.
  3. Swapping the washer type. DOE counts 25 gal for a top-loader load and 15 gal for a front-loader. In a busy morning of 2 showers, 2 shaves, 1 hand dishwashing and 1 dishwasher load, the front-loader gives 69 gal and the top-loader gives 79 gal. The second one falls in High-Usage at 75 gallons and up.
  4. Taking a rating a few gallons short as a match. DOE's wording is a rating of the demand or more. UF/IFAS puts it as matching within 1 to 2 gallons. With a demand of 65 gal, a 63 gal model is short by 2 gal and a 62 gal model by 3 gal. This page reports both as short. Ask the installer whether the counts are generous enough to accept it.
  5. Keeping 20 gallons for a different shower. In DOE's example the showers are 60 gal of the 65 gal, at DOE's average of 20 gal a shower. At 15 gal a shower, the DOE example drops from 65 gal to 50 gal. Change it only for a figure you know, since a guess low gives a rating that is too low.
  6. Looking for an EnergyGuide label on a heat pump water heater. DOE says the Federal Trade Commission requires the EnergyGuide label on new conventional storage water heaters but not on heat pump water heaters. The first hour rating of a heat pump model with a tank is in the maker's product literature, and the same rule applies to it.

Common questions about water heater size

How do I size a storage water heater?

Use the first hour rating. Count the hot water uses in the busiest single hour of the home, multiply each by DOE's average gallons for that use, and add them for the peak hour demand. Then look for a model with a first hour rating of that many gallons or more. DOE's example of 3 showers, 1 shave and 1 round of hand dishwashing adds to 65 gal by its line items, so it needs a rating of 65 gal or more. For the same example, DOE's page prints 66 gallons.

What is a first hour rating?

It is the number of gallons of hot water a heater can supply per hour, starting with a tank full of hot water, as DOE puts it. That figure depends on the tank capacity, the source of heat (burner or element) and the size of the burner or element. The federal test rule, 10 CFR 430 Appendix E, defines it as an estimate of the maximum volume of hot water a non-flow activated water heater can supply within an hour that begins fully heated.

Where do I find the first hour rating of a water heater?

On the EnergyGuide label, in the top left corner, where it reads "Capacity (first hour rating)". DOE says the Federal Trade Commission requires the label on new conventional storage water heaters but not on heat pump water heaters. For a heat pump model, or any model without the label, check the maker's product literature.

Why does DOE print 66 gallons for its example when this page shows 65?

DOE's page prints 66 gallons for this example. Its own line items add to 65 (3 x 20 + 2 + 3), and this page adds the line items. DOE's rule itself is the same either way, a rating of the demand or more. A model rated 66 gal covers both figures.

What if the model is 1 or 2 gallons under my peak hour demand?

UF/IFAS EDIS says to look for a first hour rating that matches within 1 to 2 gallons of the peak-hour demand, while DOE says to look for the demand or more. This page follows DOE and reports a 63 gal model as short by 2 gal against 65 gal. It adds the UF/IFAS note, since that source treats a rating that close as a match. Whether to accept it is for you and the installer to decide.

How many gallons per shower does the calculator use?

20 gal, which is DOE's average for a shower. You can enter your own from 5 to 40 gallons. At 15 gal a shower, DOE's example comes to 50 gal. That 15 is an example chosen for this page, and it is not a DOE or industry figure. Only the shower line uses it, and the other uses keep DOE's gallons.

Does this work for a heat pump water heater?

Yes, for one with a tank. DOE's page covers storage water heaters, including a heat pump water heater with a tank, and sizes them by first hour rating. The EnergyGuide label is not required on heat pump water heaters, so the rating comes from the maker's literature.

Does the first hour rating tell me the tank size?

No. DOE says the rating depends on the tank capacity, the source of heat and the size of the burner or element. Two models with the same tank can have different ratings, so this page compares the rating and does not give a tank volume.

What are the Very-Small, Low, Medium and High-Usage bins?

They are the draw patterns of the 24-hour test in 10 CFR 430 Appendix E, picked by first hour rating in Table I. In that table, under 18 gallons is Very-Small-Usage, 18 up to under 51 gallons is Low-Usage, 51 up to under 75 gallons is Medium-Usage, 75 gallons or more is High-Usage. A model rated at the 65 gal that DOE's example adds to falls in Medium-Usage, and so does one at the 66 gal DOE prints. The bin comes from the test and is not a size recommendation.

Is this the calculator for a tankless water heater?

No. A tankless heater has no first hour rating and is sized by the flow it must deliver and the temperature rise. The tankless water heater size calculator on this site works that case.

Used on the same job