Electrical calculators for HVAC work

The circuit for a condenser, heat pump or mini split is sized from the nameplate, not the tonnage. The breaker calculator starts from the compressor RLA and the fan motor currents, or the heat strip rating. It works out the MCA under NEC 2023 Article 440, or Article 424 for heat strips, and the largest breaker by the manufacturer method, with the 225 percent limit in 440.22 as the ceiling. A nameplate MOCP, when you enter it, governs the breaker. The wire and voltage drop calculators carry the circuit on to the conductor and the run. For a load that is not a compressor, the wire size calculator finds the smallest conductor under NEC 210.19(A)(1) and 215.2(A)(1), with 125 percent of a continuous load, and the derating calculator gives the ampacity of a given wire after the ambient, rooftop and conductor-count corrections. Running watts and amps of a unit come from the amps and watts calculator, from the capacity and EER2 or from a current reading, with starting kVA from the LRA. Another calculator turns kW, kVA or watts into amps on DC, single phase and three phase. The ground wire calculators size the equipment grounding conductor from Table 250.122 and the grounding electrode conductor from Table 250.66. Box fill and conduit fill are checked against 314.16 and the Chapter 9 fill tables. The EV charger calculator sizes the breaker and wire for a Level 2 charger at 125 percent of its current, and the service load calculator works a house's service load and size by the NEC 220.82 optional method, a first check before a heat pump or charger is added.

They are for checking a quote and talking to the electrician on the job. A licensed electrician installs the circuit, and the nameplate and local amendments govern over any number here.

Maintained by BuildSolver · Updated

Which one you need

Every tool in this section

  • Electrical for HVAC

    AC Breaker Size Calculator

    Minimum circuit ampacity and the largest breaker for an AC, heat pump or mini split, plus heat strip circuits.

    Worked from the compressor and fan currents on the nameplate. The nameplate MCA and MOCP govern, and no values are given by tonnage or model. Heat strip mode is single phase, and a licensed electrician installs the circuit.

    Based on NEC 2023 Article 440 and Article 424

  • Electrical for HVAC

    AC Wire Size Calculator

    Copper or aluminum conductor for the nameplate MCA, with the voltage drop over your run.

    Applies the 60°C (140°F) or 75°C (167°F) terminal rule, optional heat and conductor-count corrections, and the 3 percent voltage drop guideline from the Informational Note, which is not a requirement.

    Based on NEC 2023 Table 310.16, 110.14(C) and 310.15

  • Electrical for HVAC

    AC Amps and Watts Calculator

    Running watts and amps of an AC or heat pump from its capacity and EER2, watts from a current reading, and starting kVA from the LRA.

    Works at the 95°F EER2 rating point, on single or three phase. No power factor is guessed, no generator size is given, and the breaker and wire come from the nameplate.

    Based on 10 CFR 430 Appendix M1 (EER2), DOE power equations

  • Electrical

    Voltage Drop Calculator

    Volts and percent dropped over a run, the smallest wire for a target drop, and the longest run for a size.

    Single phase or balanced three phase, 120 to 480 V, copper or aluminum from 14 AWG to 4/0. Shows the Table 310.16 ampacity next to each size. The 3 percent figure is an Informational Note, not a requirement.

    Based on K method (Mike Holt), NEC 2023 Chapter 9 Table 8

  • Electrical

    Baseboard Heater Breaker Size Calculator

    Breaker, wire and circuits for electric baseboard heaters, or how many heaters fit on a 15, 20, 25 or 30 amp circuit.

    Single phase at 120, 208 or 240 V, up to two heater sizes. Conductors at 125 percent of the load, the breaker at the next standard size, and 3,840 W on a 20 A circuit at 240 V. A 240 V heater on 208 V makes 75 percent of its watts. A circuit with more than one heater is held to 30 A.

    Based on NEC 2023 Article 424 (424.4), Table 240.6(A)

  • Electrical

    Ground Wire Size Calculator

    Copper or aluminum EGC by breaker or fuse rating, scaled by circular mils when circuit conductors were upsized.

    Copper or aluminum from Table 250.122, increased by circular mil area under 250.122(B) when the ungrounded conductors are larger than the ampacity minimum, and never larger than the circuit conductors.

    Based on NEC Table 250.122 (equipment grounding conductors) and 250.122(B)

  • Electrical

    GEC Size Calculator

    Grounding electrode conductor by Table 250.66 from ungrounded conductor size, with limits at rods, Ufer electrodes and ground rings.

    Copper or aluminum service conductors, parallel sets added by area. Table 250.66 governs for a water pipe or building steel; a rod, a concrete-encased electrode or a ground ring caps the size when nothing larger connects beyond it.

    Based on NEC Table 250.66, 250.66(A), (B) and (C)

  • Electrical

    Box Fill Calculator

    Box size for wires of an outlet or junction box, by conductor, clamp, switch, receptacle and ground allowances.

    Counts each conductor, the clamp, fixture stud, device yoke and grounding allowances by 314.16(B) and checks the total against a Table 314.16(A) metal box or the volume marked on a nonmetallic box, rings included.

    Based on NEC 314.16, Tables 314.16(A) and 314.16(B)

  • Electrical

    Conduit Fill Calculator

    Percent fill, smallest trade size and maximum wire count of a raceway, by conductor and Chapter 9 fill tables.

    Conductor areas from Table 5, raceway areas from Table 4 for EMT, IMC, rigid, PVC Schedule 40 and 80, ENT and flexible metal conduit, held to 53, 31 or 40 percent by Table 1 and 60 percent for a nipple. Fill only; derating for more than three current-carrying conductors is on the wire size page.

    Based on NEC Chapter 9 fill tables, Annex C

  • Electrical

    Conduit Bend Calculator

    Bend marks and shrink for an offset in EMT or rigid conduit.

    Gives the distance between the two bends and the shrink for an offset at 10 to 60 degrees from the Gardner Bender multiplier and shrink tables, then the marks to make from the end of the conduit. Also the stub mark for a 90 degree bend from the bender deduct. Saddles are not covered; check the first bend against your own bender.

    Based on Gardner Bender

  • Electrical

    Pull Box Size Calculator

    Smallest pull or junction box from the raceways that enter it.

    Straight, angle and U pulls by wall and row under NEC 314.28(A), with the distance between entries of the same conductors. Conductors 4 AWG and larger.

    Based on NEC 314.28(A)

  • Electrical

    Fault Current Calculator

    Fault current at a transformer secondary and down three feeder runs.

    Enter the transformer kVA, percent impedance and secondary voltage, then up to three runs of copper or aluminum conductor. The result gives the full-load current, the fault current at the secondary and at the end of each run, by Bussmann's point-to-point method. Bolted three-phase or single-phase; arc flash is not calculated.

    Based on Eaton Bussmann point-to-point

  • Electrical

    EV Charger Breaker Size Calculator

    Breaker and wire size, EV charger.

    Single phase at 208 or 240 V, 12 to 80 A, one charger on its own circuit. The breaker and the conductors are at least 125 percent of the charger current (625.41, 625.42), 60 A and 4 AWG NM-B or 6 AWG THHN copper for a 48 A charger. Copper and aluminum, checks the breaker on a circuit now. Voltage drop and 120 V Level 1 are not covered.

    Based on NEC 625.41, 625.42

  • Electrical

    Service Size Calculator

    Service load and size, NEC 220.82, panel rating check.

    Adds 3 VA per sq ft, the small-appliance and laundry circuits and the fixed appliances at 100 percent of the first 10 kVA and 40 percent of the rest, then the largest heating or air-conditioning option, with heat pump supplemental heat and the compressor lockout. 120/240 V only; a calculation of the load, not an AHJ-accepted load calculation.

    Based on NEC 220.82, 230.79(C)

  • Electrical

    Ampere Calculator

    Amps from kW, kVA or watts, single or three phase, and kW from amps.

    I = kW x 1,000 / (V x PF), with 1.732 times the line-to-line voltage on three phase, and kVA without a power factor. Checked against Hammond's transformer full-load current cards and DOE's motor example. DC too. No breaker or wire size.

    Based on DOE Equation 1, transformer full-load current tables

  • Electrical

    Transformer Size Calculator

    Standard kVA size for a load, with primary and secondary amps.

    Picks the smallest listed transformer size for a load in kVA or kW, gives full-load current on both windings, and the largest breaker or fuse on each side under NEC Table 450.3(B). Transformers of 1000 V and below only.

    Based on NEC Table 450.3(B)

  • Electrical

    Wire Conductor Size Calculator

    Smallest copper or aluminum conductor for the amps of a continuous or noncontinuous load.

    The terminal column is checked against the noncontinuous load plus 125 percent of the continuous load, and the ampacity after heat and conductor-count corrections against the load itself. Breaker limits of 240.4(B) and (D), voltage drop. 14 AWG to 4/0.

    Based on NEC 2023 210.19, Table 310.16

  • Electrical

    Ampacity Derating Calculator

    Ampacity of a given conductor after ambient and bundling corrections.

    Starts from the insulation column of Table 310.16, multiplies by the ambient factor (with the rooftop adder) and the more-than-three-conductors factor, then holds the result to the terminal column. NM-B is held to 60°C (140°F). 14 AWG to 4/0.

    Based on NEC 2023 Table 310.16, 310.15(B) and (C)

  • Electrical

    Standard Breaker Size Calculator

    Table 240.6(A) breaker, fuse ratings, next size up.

    Table 240.6(A) ratings from 10 to 6,000 A plus the fuse-only 1, 3, 6 and 601 A. A conductor rounds down, or up one size under 240.4(B) up to 800 A and not on multi-receptacle branch circuits; 240.4(C) above 800 A and the 240.4(D) small-conductor limits. A load is the noncontinuous plus 125 percent of the continuous.

    Based on NEC 2023 Table 240.6(A), 240.4(B) and (C)

  • Electrical

    Generator Size Calculator

    Backup generator sizing, motor starting load, soft start.

    Running watts of the loads you pick plus the starting watts of the largest motor (Generac's method), or every start at once. A central AC or heat pump is entered from its nameplate RLA and LRA, with an optional soft start. Amps at 120 and 240 V, the worst leg, and a check against a generator's running and starting rating.

    Based on Generac sizing method, Kohler Power Systems Topics 103

  • Electrical

    Motor Horsepower Calculator

    Motor by horsepower, conductor, overload, Article 430.

    Full-load current from Table 430.248 (single phase) or 430.250 (three phase induction), conductors at 125 percent (430.22), the short-circuit and ground-fault device from Table 430.52 with Exceptions No. 1 and 2, and overload protection from the nameplate (430.32). 1/6 to 500 hp, 115 to 575 V; not hermetic compressors (Article 440).

    Based on NEC Tables 430.248, 430.250 and 430.52

  • Electrical

    Power Factor Correction Calculator

    Capacitor kVAR to raise a load from one power factor to another.

    Enter a load in kW or a motor in hp with its efficiency, and the existing and target power factor. The result gives the capacitor kVAR, the table multiplier, the kVA and line current before and after, and the kW of capacity freed. Harmonics and capacitor bank steps are not covered.

    Based on EC&M power factor correction

Other calculators

Every calculator here lists the standard it works from and what it leaves out. The numbers are for sales-phase sizing and field checks, not a permit submittal. Methodology lists the standard behind each one.