Maintained by BuildSolver · Updated
Calculator · Electrical
Electricity cost calculator
Enter the power of an appliance, the hours and days it runs and your price per kWh, and this page gives the energy in kWh and the cost per day, per month and per year. The example is the window fan from the Virginia Cooperative Extension copy of the DOE method: 200 W for 4 h a day over 120 days is 96 kWh a year, $17.43 at the 18.16 cents per kWh EIA national average residential price for August 2026. For the wire and breaker behind a load use the kW to amps calculator; for an air conditioner, the SEER2 energy cost calculator.
- Read the watts on the nameplate or in the manual. If only amps are given, switch to the amps and volts mode: power is volts times amps, times the power factor for an AC motor.
- Hours of use on a day it is used (24 at most) and the days of use in a year (365, or 366 in a leap year). For an appliance that cycles, such as a refrigerator, add the share of the time it draws full power.
- Your electricity price in cents per kWh, from the bill. The default is the EIA national average residential price, which is not your rate.
- The result gives kWh per use day, per average month and per year, and the cost of each, with the standby hint and the limits of a flat price.
Example result for the default inputs
200 W, 4 h per day, 120 days per year, 18.16 cents per kWh.
Energy per use day
0.800 kWh
Energy per year
96.00 kWh
Cost per month
$1.45 average
Cost per year
$17.43 per year
| Power known as | Power in watts |
|---|---|
| Power while running | 200 W |
| Time of use | 4 h per day, 120 days per year |
| Duty cycle | Not entered: the appliance is taken to draw its full power for all the hours of use |
| Energy per use day | 200 W x 4.00 h / 1000 = 0.800 kWh |
| Energy per year | 0.800 kWh x 120 days = 96.00 kWh |
| Energy per average month | 96.00 kWh / 12 = 8.00 kWh (10.0 days of use a month on average) |
| Price | 18.16 cents per kWh, one flat rate |
| Cost per use day | 0.800 kWh x 18.16 cents = $0.15 |
| Cost per average month | 8.00 kWh x 18.16 cents = $1.45 |
| Cost per year | 96.00 kWh x 18.16 cents = $17.43 |
| Against the U.S. average | 18.16 cents is 100 percent of 18.16 cents, the EIA August 2026 average residential price (preliminary) |
- One flat price per kWh is used. Tiered, time-of-use, seasonal and demand rates, fixed monthly charges, taxes and fuel adjustments are not modeled. Take the price from your bill, and for a load added on top of a tiered rate use the rate of the highest tier it reaches.
- No duty cycle is entered, so the appliance is counted at full power for every hour of use. That fits a heater element or a light, and overstates a refrigerator, a freezer, an air conditioner or a pump, which cycle on and off. For a refrigerator the DOE guidance is to divide the plugged-in time by three, a duty of about 33 percent.
- Many devices draw power when switched off. Each 1 W left on all year is 8.76 kWh, $1.59 at this price. Add the standby draw of a TV, a charger or a game console as a separate line, or unplug it.
- Treat the result as an estimate. Wattage labels are often maximums, use varies, and the price on a bill is rarely a single number. A plug-in watt meter measures an appliance directly.
For estimation purposes only. Consult a licensed engineer for final designs.
Sign up with your email. Back on this page in the same browser, your inputs are filled in. No card.
Free without signup
How the running cost is found
The page turns the power into kilowatts, multiplies by the hours the appliance runs to get kWh, scales that to a year and to an average month, and multiplies by the price. That first line is the DOE formula for estimating appliance energy use. You supply the price: a flat rate per kWh, in cents.
- Power from amps and volts
W = V x I (DC), W = V x I x PF (single-phase AC)Used only when the nameplate gives no watts. 12 V x 5 A is 60 W on DC. 120 V x 10 A at PF 0.8 is 960 W, against 1,200 W at PF 1.- Average power with a duty cycle
W_avg = W x (duty percent / 100)For an appliance that cycles. A 150 W refrigerator that runs a third of the time averages 50 W, and 438 kWh a year instead of 1,314 kWh at full power the whole time.- Energy per use day
kWh per day = W_avg x hours per day / 1000200 W x 4 h / 1000 = 0.8 kWh. A 1,500 W heater for 1 h is 1.5 kWh. 1 kW is 1,000 W, so a kilowatt-hour is a kilowatt used for one hour.- Energy per year and per average month
kWh per year = kWh per day x days per year; kWh per month = kWh per year / 120.8 kWh x 120 days = 96 kWh a year, the window fan example of the Virginia Cooperative Extension copy of the DOE method, and 8 kWh in an average month. A device used 365 days a year has 365 / 12 = 30.4 use days a month, and 366 days gives 30.5.- Cost
cost = kWh x price in cents per kWh / 10096 kWh at 8.5 cents is $8.16 a year, the figure in the extension copy, and at the 18.16 cent default it is $17.43. DOE's own example, a 1,500 W kettle used 1 h a day all year, is 547.5 kWh and $60.23 a year at 11 cents, and this formula gives the same. The cost per month is the year cost over 12, and money is shown to the cent.
Seven appliances at the national average price
Each row is worked with the same function as the form, at 18.16 cents per kWh. Standby load at 0.5 W, 24 h a day, 365 days costs $0.80 a year, and electric dryer at 5,000 W, 1 h a day, 200 days uses 1,000 kWh and costs $181.60.
| Appliance | Use | kWh per day | kWh per year | Cost per month | Cost per year |
|---|---|---|---|---|---|
| Standby load | 0.5 W, 24 h a day, 365 days | 0.012 | 4.4 | $0.07 | $0.80 |
| LED bulb | 9 W, 5 h a day, 365 days | 0.045 | 16.4 | $0.25 | $2.98 |
| Window fan | 200 W, 4 h a day, 120 days | 0.800 | 96.0 | $1.45 | $17.43 |
| Desktop PC and monitor | 270 W, 4 h a day, 365 days | 1.080 | 394.2 | $5.97 | $71.59 |
| Refrigerator | 150 W, 24 h a day, 365 days, 33.3 percent duty | 1.199 | 437.6 | $6.62 | $79.46 |
| Space heater | 1,500 W, 6 h a day, 90 days | 9.000 | 810.0 | $12.26 | $147.10 |
| Electric dryer | 5,000 W, 1 h a day, 200 days | 5.000 | 1,000.0 | $15.13 | $181.60 |
The refrigerator row uses a duty cycle of 33.3 percent, DOE's divide-by-three rule: at full power all day the same 150 W unit would use 1,314 kWh. The wattages are round figures for the example. A nameplate or a plug-in watt meter replaces them, and the price is the EIA national average, not your rate.
Standards and data sources
- U.S. Department of Energy, Energy Saver, Estimating Appliance and Home Electronic Energy Use - The method behind the page: energy use per day is wattage times hours used per day divided by 1,000, multiplied by the days of use per year for annual use and by the utility rate per kWh for cost. The article also gives the amps times volts estimate when no wattage is listed, the divide-by-three rule for a refrigerator, and the advice on devices that draw power when switched off. Its worked examples are an electric kettle, 1,500 W for 1 hour a day all year, 547.5 kWh and $60.23 a year at 11 cents per kWh, and a paper shredder rated 3 A at 120 V, 360 W. energy.gov refuses automated readers, so the article was read in its web.archive.org copy of July 1, 2026 (page dated May 12, 2026).
- Virginia Cooperative Extension, Estimating Appliance and Home Electronic Energy Use (publication 2901-9014, 2020) - An extension copy of the same method with its own examples: the formula in kWh, the window fan of 200 W for 4 hours a day over 120 days, which is 96 kWh, and its cost of $8.16 a year at 8.5 cents per kWh. The window fan is this page's default; it is the extension's example, not one on the energy.gov page. The publication says it was developed as part of the NASULGC/DOE Building Science Community of Practice.
- U.S. Energy Information Administration, Electric Power Monthly, Table 5.6.A, Average Price of Electricity to Ultimate Customers by End-Use Sector, by State, August 2026 and August 2025 - The default price. In the table released October 23, 2026, the U.S. total residential price is 18.16 cents per kWh for August 2026 (preliminary) and 17.57 cents for August 2025. It is a national monthly average. Prices differ by utility and by month, and no state or utility rate is used on this page.
Limitations of this calculator
- This page estimates the energy and the cost of one appliance from the numbers you give it. It is a planning aid for a quote, a comparison or a rough budget, not a bill. Your meter, your utility's tariff and the way the appliance is used decide what you pay.
- The price is one flat number of cents per kWh. Tiered rates, time-of-use rates, seasonal rates, demand charges, fixed monthly charges, taxes and fuel adjustments are not modeled. The default of 18.16 cents is the EIA national average residential price for August 2026 (preliminary), not a rate you can be billed. Use the price on your own bill, and for a load added to a tiered rate the rate of the tier it reaches.
- The power is taken as constant while the appliance runs. Many appliances draw less than their nameplate figure most of the time and more while they start. A nameplate in amps is normally the rated maximum. A duty cycle you estimate is an estimate, and a plug-in watt meter or a clamp meter gives a better number than any label.
- Amps and volts are converted for a DC load (W = V x I) and for a single-phase AC load with the power factor you enter (W = V x I x PF). Three-phase equipment needs a factor of 1.732 that this page does not apply, and a load with a poor power factor and no nameplate in watts needs a measurement.
- Standby and phantom loads are not added for you. Many devices draw power when switched off, from a fraction of a watt to several watts. Enter them as a separate appliance running 24 hours, or use the hint in the result.
- The month is the average month of the year, the year divided by 12. For a seasonal appliance it is not the cost of a month of use: a fan used 120 days a year has about 10 use days in an average month, but all of its energy falls in the months it runs.
- This page does not compare the efficiency of two appliances, work out a payback period, or estimate the heating or cooling load of a building. Use the other calculators for those.
- Values outside the ranges are refused with a message: power from 0.01 W to 1,000,000 W, current and voltage up to 1,000 A and 1,000 V, up to 24 hours a day, up to 366 days a year, a duty cycle above 0 and up to 100 percent, a price above 0 and up to 500 cents per kWh ($5). The cap on the price is this page's own, not a tariff limit.
Common mistakes when estimating electricity cost
- Mixing up watts and kilowatts. A 1,500 W heater run for 1 hour uses 1.5 kWh, not 1,500 kWh. Divide watts by 1,000 to get kilowatts. A price in cents per kWh then gives $0.27 for that hour at 18.16 cents.
- Typing the price in dollars. The price field is in cents. 18.16 cents per kWh is $0.1816. Typing 0.1816 gives the fan a cost of $0.17 a year instead of $17.43, a hundred times too low. The result warns when the price is under 1 cent.
- Counting a cycling appliance at full power. A 150 W refrigerator is not drawing 150 W for 24 hours. At full power all day it would use 1,314 kWh a year, $238.62. DOE's rule is to divide the plugged-in time by three; that gives 438 kWh and $79.54. Use the duty cycle field for it, or a watt meter.
- Forgetting how many days a year it runs. The window fan at 200 W and 4 h a day uses 96 kWh over 120 days, $17.43 a year. Treated as a year-round load, the same fan would show 292 kWh and $53.03. Enter the days it is really used.
- Ignoring standby power. A device at 5 W in standby for 20 hours a day uses 36.5 kWh a year, $6.63 at 18.16 cents, with nothing switched on. Each watt left on all year is 8.76 kWh. A power strip switch or unplugging removes it.
- Using volts times amps for a motor. 120 V x 10 A is 1,200 VA. A motor at a power factor of 0.8 draws 960 W of real power, and the meter bills real power. Using volts times amps overstates the energy by 25 percent in this case. Enter the power factor in the AC mode.
Common questions about electricity cost
How do you calculate the cost of running an appliance?
Multiply the watts by the hours of use and divide by 1,000 to get kWh, then multiply by the price per kWh. The Virginia Cooperative Extension copy of the DOE method works a window fan: 200 W x 4 h a day x 120 days / 1000 = 96 kWh a year. At 8.5 cents per kWh that is $8.16 a year, and at the 18.16 cent national average it is $17.43, or about $1.45 an average month.
How many kWh does an appliance use?
Watts divided by 1,000 times the hours it runs. A 100 W bulb lit for 10 h is 1 kWh a day, 365 kWh over a year at 10 h a day. A 1,500 W space heater for 1 hour is 1.5 kWh. Appliances that cycle, such as a refrigerator, need a duty cycle: the same 150 W unit uses 438 kWh a year at a third of the time.
What is the average price of electricity per kWh?
The EIA's Electric Power Monthly, Table 5.6.A, puts the U.S. average residential price at 18.16 cents per kWh for August 2026 (preliminary, released October 23, 2026), against 17.57 cents for August 2025. That is a national monthly average, and the price you pay depends on your utility, the month and your rate plan. Use the price on your bill. This page does not use state rates.
How do I find the cost if the label gives only amps and volts?
Power is volts times amps. DOE's article says to find the current draw in amperes and multiply by the voltage. For DC, 12 V x 5 A is 60 W. For single-phase AC with a motor, multiply by the power factor too: 120 V x 10 A x 0.8 is 960 W. A nameplate current is usually the maximum, so the result is an upper estimate.
How do I handle a refrigerator or an air conditioner that cycles?
Enter the share of the time it draws full power in the duty cycle field. DOE's guidance for a refrigerator is to divide the plugged-in time by three, a duty of about 33 percent. A 150 W refrigerator then uses 438 kWh a year, $79.54 at 18.16 cents, instead of 1,314 kWh counted at full power all day. A plug-in watt meter over a week gives a better figure.
How much does standby power cost?
Each 1 W that stays on all year is 8.76 kWh. A draw of 0.5 W round the clock is 4.38 kWh a year, $0.80 at 18.16 cents. A device at 5 W in standby for 20 hours a day is 36.5 kWh and $6.63. One device is small, and a house of them adds up. Unplugging or a switched power strip stops it.
Does the calculator handle tiered or time-of-use rates?
No. It uses one flat price per kWh. With a tiered plan, enter the rate of the tier the appliance's energy lands in. With a time-of-use plan, enter the rate of the hours it runs, or work out the peak and off-peak hours as two separate lines. Demand charges and fixed monthly fees are not included.
How many days are in a month for this calculation?
The page takes the month as the year divided by 12, which is 365 / 12 = 30.4 days for a device used every day, and 30.5 days in a leap year of 366. The monthly cost is the yearly cost over 12. For a seasonal appliance such as a 120 day fan, that is the average month of the year, 8 kWh, not a month of use.