Sizing from the International Plumbing Code tables for the rainfall rate you enter, for a quote or a first layout. The edition and amendments the local jurisdiction has adopted decide, and so does the rate it sets. Half-round gutters only. Not a roof drain or storm pipe design.

Maintained by BuildSolver · Updated

Calculator · Plumbing

Gutter and downspout size calculator

Enter the roof area, the design rainfall and the number of downspouts, and this page gives the flow the roof sheds and the sizes the IPC tables read for it. A 1,200 sq ft roof at 4 in/h sheds 49.9 gpm (0.0104 x 4 x 1,200). On one downspout that is a 2.5 in round leader and a 5 in half-round gutter; on two downspouts, 25.0 gpm each, a 2 in leader and a 4 in gutter. For the drain pipe of the same building use the sanitary drain pipe size calculator; for the vents on the same roof, the attic ventilation calculator.

  1. The horizontally projected area in square feet, the footprint seen from above, plus 0 or the area of a wall that drains onto the roof.
  2. The rate in inches per hour that your local code sets, usually the 100-year, 1-hour rainfall.
  3. The number of downspouts the roof drains to, taken in equal shares, and the slope of the gutter, 1/8 in per ft unless you hold less.
  4. The result gives the flow in gpm, the round downspout size and the half-round gutter size from the IPC tables, with the roof area each can serve.

Flow, round downspout and half-round gutter size from the IPC tables for the rainfall you enter. No roof drains, storm piping, overflow or K-style gutters.

The horizontally projected area, the footprint of the roof seen from above including the overhangs, not the sloped surface. Add the roof sections that drain into the same gutters.

A wall that rises above a lower roof sheds its rain onto it. Half of its area is added to the roof, as IPC 1106.4 does. Enter 0 if there is none.

The rate your local code sets, usually the 100-year, 1-hour rainfall. IPC Appendix B lists cities, for example Chicago 3.0, Atlanta 3.7 and Miami 4.7. NOAA's Precipitation Frequency Data Server gives a point value.

The roof is taken to drain to them in equal shares. A gutter run with a downspout at each end sends half of its roof each way.

The table gives half-round gutters at 1/8 in per ft, and at 1/16 only for the 8 and 10 in sizes.

Example result for the default inputs

Roof 1,200 sq ft, wall 0 sq ft, 4 in/h, 2 downspouts, gutter slope 1/8 in per ft.

Flow

49.9 gpm

Downspout, round

2 in

Half-round gutter at 1/8 in per ft

4 in

Calculation details
Effective roof area1,200 sq ft (no wall added)
Flow0.0104 x 4 in/h x 1,200 sq ft = 49.9 gpm
Flow per downspout49.9 / 2 = 25.0 gpm
Downspout2 in round, 30 gpm (rectangular sizes in the same row: 2 x 2 or 1 1/2 x 2 1/2)
Roof area one downspout of that size serves30 / (0.0104 x 4) = 721 sq ft
Gutter4 in half-round at 1/8 in per ft, 39 gpm, about 938 sq ft of roof
  • The roof is taken to drain to the downspouts in equal shares. If one downspout takes more, size the gutter and leader for its share.

For estimation purposes only. Consult a licensed engineer for final designs.

Get this result as a PDF, free account

Sign up with your email. Back on this page in the same browser, your inputs are filled in. No card.

Size the drain pipe

Free without signup

How the gutter and downspout size is found

The page follows the International Plumbing Code. It converts the rain falling on the roof into a flow in gallons per minute with Equation 11-1, adds half of any wall that drains onto the roof, shares the flow between the downspouts, and reads the smallest leader and the smallest half-round gutter whose table capacity is not below that share.

Effective roof area
A = roof area (plan) + 1/2 x wall area draining onto the roof1,000 sq ft of roof under a 400 sq ft wall counts as 1,200 sq ft.
Flow
Q (gpm) = 0.0104 x R x A, R in inches per hour, A in sq ft1,200 sq ft at 4 in/h is 0.0104 x 4 x 1,200 = 49.9 gpm. The 0.0104 is 1 in of rain on 1 sq ft in an hour, about 0.0104 gpm.
Flow per downspout
q = Q / number of downspoutsThe 49.9 gpm on two downspouts is 25.0 gpm each.
Downspout
smallest leader size with table gpm at least qTable gpm for 2, 2 1/2, 3, 4, 5, 6 and 8 in round: 30, 54, 92, 192, 360, 563 and 1,208. 49.9 gpm on one downspout reads 2.5 in; 25.0 gpm reads 2 in.
Gutter
smallest half-round size with table gpm at least q at the slopeAt 1/8 in per ft, 4, 5, 6, 8 and 10 in carry 39, 74, 110, 247 and 472 gpm. 49.9 gpm reads 5 in; 25.0 gpm reads 4 in.

One roof in six cities

Each row is a 2,000 sq ft roof on two downspouts with a half-round gutter at 1/8 in per ft, worked with the same function as the form. Rates are the 100-year, 1-hour values of IPC Appendix B, Table B101. That roof needs a 4 in gutter in Seattle and a 5 in gutter in Miami.

Flow, downspout and gutter for one roof at six city rainfall rates
CityRainfallFlow, gpmPer downspout, gpmDownspout, inGutter, in
Seattle1.4 in/h29.114.624
Denver2.4 in/h49.925.024
Chicago3.0 in/h62.431.22.54
Atlanta3.7 in/h77.038.52.54
Houston4.6 in/h95.747.82.55
Miami4.7 in/h97.848.92.55

Use the footprint, not the sloped surface: a 1,200 sq ft footprint under a 6/12 roof has a surface near 1,342 sq ft, and using that figure would give 55.8 gpm instead of 49.9.

Standards and data sources

Limitations of this calculator

  • This page sizes a leader and a half-round gutter from the International Plumbing Code tables for the rainfall rate you enter. It is a sizing estimate for a quote or a first layout, not a drainage design. The edition and the amendments your jurisdiction has adopted decide, and some jurisdictions size gutters by other rules or by the manufacturer's rating.
  • The rainfall rate is yours to set. The page does not look up a site. City rates in IPC Appendix B are informative, and NOAA point values can differ from them; use the rate the local authority requires.
  • The gutter table is for semicircular gutters. K-style, box and other shapes have a different section and are not in the table the page reads; use the maker's flow rating for them. Rectangular entries of the table are not used here.
  • The leader answer is a round size. The table also lists rectangular sizes, and the page prints them as listed. A 2 x 3 or a 3 x 4 downspout is not a listed size; pick the listed size that is larger.
  • The roof is taken to drain to the downspouts in equal shares and each gutter is sized for the share of one downspout. A roof that drains unevenly needs the largest share entered as its own case.
  • The table capacities are for clear gutters and pipes. Leaves, a long run, a slope that is not held, outside corners, a downspout that discharges into a pipe or an overflow that is not provided are not worked.
  • Roof drains, storm piping below grade, scuppers, overflow and secondary drainage are different sections of the code and are outside this page.
  • Values outside the field ranges are not accepted: roof area 100 to 100,000 sq ft, wall area 0 to 50,000 sq ft, rainfall 1 to 12 in/h and 1 to 20 downspouts. A flow above the 8 in leader (1,208 gpm per downspout) is refused, and above the largest gutter of the table the page gives no gutter size.

Common mistakes when sizing gutters and downspouts

  1. Using the sloped roof surface. The code takes the horizontally projected area, because rain falls on the footprint. A 1,200 sq ft footprint under a 6/12 roof has a surface of about 1,342 sq ft; using it gives 55.8 gpm in place of 49.9.
  2. Using an ordinary rain instead of the design rate. A 2,000 sq ft Houston roof at an everyday 2 in/h sheds 41.6 gpm and reads a 4 in gutter on two downspouts. At the 4.6 in/h of IPC Appendix B it is 95.7 gpm and a 5 in gutter, with 2.5 in downspouts.
  3. Leaving out the wall above a lower roof. A wall that drains onto a lower roof adds half of its area. 1,000 sq ft of roof alone is 41.6 gpm at 4 in/h; with a 400 sq ft wall above it, it is 49.9 gpm.
  4. Putting the whole roof on one downspout. The Denver example roof (2,000 sq ft at 2.4 in/h) is 49.9 gpm. On one downspout that reads a 2.5 in leader and a 5 in gutter; on two it is 25.0 gpm each, a 2 in leader and a 4 in gutter.
  5. Reading the gutter size off a K-style catalog. The gutter table is for semicircular gutters. A K-style or box gutter of the same nominal width has a different section, so the half-round answer does not carry over. Use the flow rating the maker publishes for the profile.
  6. Taking a downspout size the table does not list. A 2 x 3 downspout is common and is not a table size. For the 3,000 sq ft Atlanta roof on two downspouts, 57.7 gpm each reads a 3 in round leader (2 x 4 or 2 1/2 x 3). Choose the listed size that is larger, not the nearest.

Common questions about gutter and downspout size

How do I size a gutter and downspout?

Find the flow the roof sheds with Q = 0.0104 x R x A, with R the design rainfall in inches per hour and A the projected roof area in sq ft. A 1,200 sq ft roof at 4 in/h is 49.9 gpm. Divide it by the downspouts, then read the smallest leader and gutter in the IPC tables whose capacity is not below that share: on two downspouts, 25.0 gpm each, a 2 in round leader and a 4 in half-round gutter.

What rainfall rate should I use?

The rate your local code sets, usually the 100-year, 1-hour rainfall for the site. IPC Appendix B lists cities, for example Seattle 1.4, Denver 2.4, Chicago 3.0, Atlanta 3.7, Houston 4.6 and Miami 4.7 inches per hour. NOAA's Precipitation Frequency Data Server gives a point value, which can differ from the appendix.

How many gpm does a downspout carry?

From the IPC leader table, a 2 in round downspout carries 30 gpm, 2 1/2 in 54, 3 in 92, 4 in 192, 5 in 360, 6 in 563 and 8 in 1,208. The same rows list rectangular sizes, for example 2 x 4 or 2 1/2 x 3 in with the 3 in round and 3 x 4 1/4 or 3 1/2 x 4 in with the 4 in round.

How much roof can one downspout drain?

It depends on the rainfall. A 2 in round leader (30 gpm) serves about 721 sq ft at 4 in/h and about 1,202 sq ft at 2.4 in/h. Read the area for the leader the page picks in the result table.

What size gutter do I need?

IPC's gutter table gives half-round gutters at 1/8 in per ft: 4 in carries 39 gpm, 5 in 74, 6 in 110, 8 in 247 and 10 in 472. A 1,200 sq ft roof at 4 in/h on two downspouts is 25.0 gpm per downspout, a 4 in gutter; on one downspout it is 49.9 gpm, a 5 in gutter.

Do I count the wall that meets the roof?

Yes, where a wall diverts rain onto the roof. IPC 1106.4 adds one-half of that wall area to the roof area. A 400 sq ft wall above 1,000 sq ft of roof counts as 1,200 sq ft, 49.9 gpm at 4 in/h.

Is a 5 in K-style gutter the same as a 5 in half-round?

No. The table in this calculator is for semicircular gutters. A K-style gutter has a different section, so use the maker's flow rating for it. The page does not convert between shapes.

What if the flow is more than the table covers?

Add downspouts so each carries less. The page refuses a flow above 1,208 gpm per downspout, and above 472 gpm per gutter run (1/8 in per ft) it gives no gutter size. A roof that large is a roof drain design, which is a different section of the code.

Used on the same job