Maintained by BuildSolver · Updated
Calculator · Plumbing
Septic tank size calculator
Septic rules size the tank from bedrooms, not from a water meter. In New York a four bedroom house needs 1,250 gallons of liquid volume, in the International Private Sewage Disposal Code 1,200 gallons and in Washington 1,000 gallons. All three read 1,000 gallons at three bedrooms. New York counts a garbage grinder as one more bedroom, which takes a three bedroom house to 1,250 gallons. Whatever this page shows, the health department of your county or state sets the number that is permitted, and it can differ from all three tables. The drainfield is a separate calculation from the soil. For the pipe work around the tank, use the sanitary drain pipe size calculator; for a rural house's water side, the well pressure tank size calculator.
- Choose New York 75-A, Washington WAC 246-272A-0232 or the International Private Sewage Disposal Code. Use the one that matches where the system is permitted.
- Count bedrooms the way the health department does. Say whether a garbage grinder is installed; New York counts it as one more bedroom.
- The result gives the minimum liquid volume in gallons, the table row it comes from and the same house in the other two tables. A daily flow is optional and only shows the days of flow the tank holds.
Example result for the default inputs
New York, 10 NYCRR Appendix 75-A, 4 bedrooms.
Minimum tank volume
1,250 gal
Bedrooms counted
4
Across the three tables
1,000 to 1,250 gal
| Table row | NY 75-A, 75-A.6, Table 3. 4 bedrooms: 1,250 gal |
|---|---|
| Same house, other tables | NY 75-A 1,250 gal; WA 1,000 gal; IPSDC 1,200 gal |
| Not sized here | The soil absorption area (it depends on the perc rate and soil), the pump chamber, compartments and baffles, the effluent filter, setbacks and the tank material. |
| Who decides | The county or state health department sets the minimum that is enforced. Only these three published tables are read; another state can differ. |
- The three tables give 1,000 to 1,250 gal for this house. Use the table of the jurisdiction the system is permitted in, and ask the health department if it has its own.
For estimation purposes only. Consult a licensed engineer for final designs.
Sign up with your email. Back on this page in the same browser, your inputs are filled in. No card.
Free without signup
How the tables set the tank volume
A bedroom-based septic rule does not measure the water a house uses. It counts bedrooms as a stand-in for the people who can live there and reads a minimum liquid volume from a table. There are three tables on this page. New York and Washington step up by 250 gallons for each bedroom past a point, and the model code has its own row for every count from one to eight. The tank volume is a lookup, not a computation, so each row below says which printed row it reads.
- New York, 10 NYCRR 75-A.6 Table 3
n <= 3: 1,000 gal; 4: 1,250; 5: 1,500; 6: 1,750; n > 6: 1,750 + 250 x (n - 6)One, two or three bedrooms read 1,000 gal. Four bedrooms read 1,250 gal, and eight read 2,250 gal by the 250 gal rule past six.- New York garbage grinder
V = max(table(n + 1), table(n) + 250) when a grinder is installedThe Table 3 note counts a grinder as an additional bedroom, so 3 bedrooms with a grinder read as 4 and need 1,250 gal instead of 1,000 gal.- Washington, WAC 246-272A-0232(2)(a) Table VII
n <= 4: 1,000 gal; n > 4: 1,000 + 250 x (n - 4)Four or fewer bedrooms read 1,000 gal, and each additional bedroom adds 250 gal, so five bedrooms read 1,250 gal.- International Private Sewage Disposal Code, Table 802.7.1
n = 1..8: 750, 750, 1,000, 1,200, 1,425, 1,650, 1,875, 2,100 galTable values for one- and two-family dwellings. Four bedrooms read 1,200 gal and five read 1,425 gal. Section 802.7 sets a floor of 750 gal for any tank.- Spread across the tables
min and max of the three volumes for the same nFour bedrooms read 1,000 gal in Washington, 1,200 gal in the model code and 1,250 gal in New York. At three bedrooms all three read 1,000 gal.- Days of flow held
days = V / daily flowOnly when you enter a daily flow. 1,000 gal against 600 gal/day is 1.7 days. This is arithmetic on your number, not a rule of any of the three texts.
Eight houses through the same tables
The first two rows are New York at three and four bedrooms, 1,000 and 1,250 gal. Row three adds a garbage grinder to the three bedroom house and lands on 1,250 gal. Washington at five bedrooms is 1,250 gal and the model code at five is 1,425 gal. The last row is eight bedrooms in New York, 2,250 gal.
| House | Table | Bedrooms | Counted | Minimum, gal | NY, gal | WA, gal | IPSDC, gal |
|---|---|---|---|---|---|---|---|
| Three bedrooms, New York | NY 75-A, no grinder | 3 | 3 | 1,000 | 1,000 | 1,000 | 1,000 |
| Four bedrooms, New York | NY 75-A, no grinder | 4 | 4 | 1,250 | 1,250 | 1,000 | 1,200 |
| Three bedrooms with a grinder, New York | NY 75-A, grinder | 3 | 4 | 1,250 | 1,250 | 1,000 | 1,000 |
| Five bedrooms, Washington | WAC 246-272A-0232 | 5 | 5 | 1,250 | 1,500 | 1,250 | 1,425 |
| Four bedrooms, Washington | WAC 246-272A-0232 | 4 | 4 | 1,000 | 1,250 | 1,000 | 1,200 |
| Four bedrooms, IPSDC | IPSDC Table 802.7.1 | 4 | 4 | 1,200 | 1,250 | 1,000 | 1,200 |
| Five bedrooms, IPSDC | IPSDC Table 802.7.1 | 5 | 5 | 1,425 | 1,500 | 1,250 | 1,425 |
| Eight bedrooms, New York | NY 75-A, no grinder | 8 | 8 | 2,250 | 2,250 | 2,000 | 2,100 |
Behind those rows are the three tables, bedroom by bedroom, without a garbage grinder.
| Bedrooms | NY 75-A, gal | WA, gal | IPSDC, gal |
|---|---|---|---|
| 1 | 1,000 | 1,000 | 750 |
| 2 | 1,000 | 1,000 | 750 |
| 3 | 1,000 | 1,000 | 1,000 |
| 4 | 1,250 | 1,000 | 1,200 |
| 5 | 1,500 | 1,250 | 1,425 |
| 6 | 1,750 | 1,500 | 1,650 |
| 7 | 2,000 | 1,750 | 1,875 |
| 8 | 2,250 | 2,000 | 2,100 |
New York and Washington print rows up to six and four bedrooms and add 250 gallons for each bedroom after that. The model code prints every count from one to eight. Where a state or county has its own table, that one is used instead.
Standards and data sources
- New York, 10 NYCRR Appendix 75-A, section 75-A.6 Septic tanks, Table 3 Minimum Septic Tank Capacities (Cornell LII copy) - The 1, 2 or 3 / 4 / 5 / 6 bedroom rows (1,000, 1,250, 1,500 and 1,750 gal with 27, 34, 40 and 47 sq ft of liquid surface), 250 gal for each bedroom beyond six, the garbage grinder counted as an additional bedroom (and 250 gal of added capacity for a grinder, 75-A.6(b)(1)(ix), as read in the Cornell copy), and an expansion attic counted as an additional bedroom.
- Washington, WAC 246-272A-0232 Septic tanks, Table VII Required Minimum Liquid Volumes of Septic Tanks - Subsection (2)(a) for a single-family residence: 1,000 gal for four or fewer bedrooms and 250 gal for each additional bedroom. Subsection (2)(b), other residential sources, sets 250 gal per bedroom with a 1,000 gal minimum, and (2)(c) sets three times the design flow for a non-residential source.
- International Private Sewage Disposal Code 2021, Chapter 8 Tanks, section 802.7 and Table 802.7.1 (Virginia edition at UpCodes) - The 750 gal minimum liquid capacity and the bedroom table for one- and two-family dwellings, one through eight bedrooms. The Virginia edition is the copy read; another state's adopted edition can carry different amendments.
Limitations of this calculator
- This page reads a minimum tank volume from three published tables. It does not approve a septic system. The county or state health department, or the local authority having jurisdiction, sets the volume that is enforced, and many states and counties have their own table or their own amendments.
- Only New York, Washington and the model code are read. A state that is not on the list is not approximated from them: each state writes its own onsite wastewater rule, and its numbers can differ from all three.
- The soil absorption area is not sized. The drainfield, mound or trench depends on the perc rate or soil evaluation, the loading rate and the site, and none of that is in a bedroom table. A tank that meets its table says nothing about whether the soil can take the effluent.
- A bedroom is a bedroom as the health department counts it. A room that can be used for sleeping, a finished basement or an expansion attic can count. New York says so for an expansion attic. Count the way the permit will.
- The garbage grinder rule is applied to the New York table only, because only that text says it counts as an extra bedroom. The Washington table has no footnote and the model code table has no grinder note, so a grinder is not added under them. Ask whether your health department adds volume.
- Compartments, baffles, outlet filters, the liquid depth, the pump chamber, the tank material, risers, lids, setbacks and the share of the volume in the first compartment are separate requirements. They are not checked here.
- A daily flow, when entered, only gives the days of flow the tank holds. The bedroom tables assume household use. Non-household buildings are sized from design flow under the rules of the state, and the Washington figure of three times the design flow is shown for comparison only.
- Tank volume here is liquid volume in US gallons. A tank's nominal size and its liquid capacity can differ, so the manufacturer's rated liquid capacity and the health department's approved tank list govern the purchase.
- Entries are whole bedrooms from 1 to 8 and a daily flow from 50 to 10,000 gal/day. A larger house is an individual design for the health department.
Common mistakes with septic tank size
- Using one state's table in another state. A four-bedroom house reads 1,000 gal in Washington, 1,200 gal in the model code and 1,250 gal in New York. The tank is sized to the table of the jurisdiction that issues the permit, so look up that one.
- Forgetting the garbage grinder in New York. Three bedrooms with a grinder are counted as 4 in Table 3, which is 1,250 gal and not 1,000 gal. The grinder is one more bedroom for the tank, and for one or two bedrooms the New York rule of 250 gallons of added capacity for a grinder gives 1,250 gal. The rules apply to a grinder installed at construction or one that can reasonably be expected later.
- Sizing to the listed bedrooms when the permit counts more. A den, an office with a closet, a finished basement or an expansion attic can be counted as a bedroom. Going from four to five bedrooms moves New York from 1,250 to 1,500 gal and Washington from 1,000 to 1,250 gal. Ask the health department how it counts.
- Reading the tank volume as the whole septic system. The tank holds and pretreats the sewage. The soil absorption field is sized from the perc rate or soil evaluation, and it is the part that fails when it is too small. A bedroom table gives neither its size nor its depth.
- Rounding a table row down to the next stock size. The tables give a minimum liquid volume. Four bedrooms in the model code is 1,200 gal, and a nominal 1,000 gal tank is below it. Buy the next size up that the health department's approved list carries, and check the liquid capacity on the data sheet.
- Entering a flow and expecting a different tank. The daily flow field gives days of flow held. Four bedrooms in Washington is 1,000 gal against 600 gal/day, 1.7 days, and the bedroom table does not change with the flow. Only a non-residential source in Washington is sized from the flow, at three times it.
Common questions about septic tank size
What size septic tank do I need for a 3 bedroom house?
1,000 gallons is the minimum liquid volume in all three tables read here: New York Table 3, Washington Table VII and the model code Table 802.7.1. The health department of the county or state sets the number that is enforced.
What size septic tank do I need for a 4 bedroom house?
It depends on the table. New York reads 1,250 gallons, the International Private Sewage Disposal Code reads 1,200 gallons and Washington reads 1,000 gallons. Use the table of the jurisdiction that issues the permit.
How much does each extra bedroom add to the septic tank?
250 gallons in New York for each bedroom beyond six and in Washington for each bedroom beyond four. In New York that makes 2,250 gallons for eight bedrooms. The model code lists each count instead: 1,200 gallons for four, 1,425 for five and 2,100 for eight.
Does a garbage disposal change the septic tank size?
In New York it does. The Table 3 note counts a garbage grinder as an additional bedroom, so a three bedroom house reads as four and needs 1,250 gallons instead of 1,000. The Washington table and the model code table have no grinder note. Ask the health department if you are elsewhere.
What is the smallest septic tank allowed?
The International Private Sewage Disposal Code sets a minimum liquid capacity of 750 gallons, and its table gives that for one and two bedrooms (750 gallons). New York and Washington start at 1,000 gallons. Your state can set a different floor.
Does the septic tank size set the size of the drainfield?
No. The tank volume comes from the bedroom count. The soil absorption area comes from the soil, the perc rate or soil evaluation and the design flow. This page does not size the drainfield, and a bigger tank does not replace a larger field.
Why do the three tables disagree?
They are written by different bodies for different conditions. At three bedrooms they agree at 1,000 gallons. At five bedrooms Washington reads 1,250 gallons, the model code 1,425 gallons and New York 1,500 gallons.
Is my state on this page?
Only New York, Washington and the model code are read, because those are the open texts with a table by bedroom that were checked. The number for any other state is that state's own. Look up your state's onsite wastewater rule or ask the county health department.