Calculators
Refrigerant and system check calculators
Charging and checking a system comes down to a few readings: suction and liquid line pressures and temperatures, indoor wet-bulb, outdoor dry-bulb, and the temperatures across the coil. These calculators turn those readings into superheat, subcooling and split.
Pressure-temperature data comes from CoolProp and is checked against manufacturer charts. For blends with glide, the calculators read the dew line for superheat and the bubble line for subcooling. The manufacturer's charging chart and installation instructions still govern.
Maintained by BuildSolver · Updated
Which one you need
- Superheat or subcooling from gauge readings: Superheat and Subcooling Calculator
- Saturation temperature at a gauge pressure: Refrigerant PT Chart
- Charge to add for a long line set: Line Set Charge Calculator
- Is the split across the coil normal: AC Temperature Split Calculator
- Is the furnace temperature rise within the rating plate range: Furnace Temperature Rise Calculator
Every tool in this section
Refrigerant charge
Superheat and Subcooling Calculator
Superheat and subcooling from gauge readings for R-410A, R-454B, R-32 and R-22.
Reads the dew point line for superheat and the bubble point line for subcooling, and gives a fixed-orifice target from indoor wet-bulb and outdoor dry-bulb.
Based on CoolProp PT data, manufacturer charging charts
Refrigerant charge
Refrigerant PT Chart
Saturation pressure from temperature and temperature from gauge pressure for R-454B, R-410A, R-32 and R-22.
Shows the dew and bubble point lines and the glide on blends, with an optional elevation correction for gauges above sea level. Refuses readings outside -40 to 140°F instead of extrapolating.
Based on CoolProp PT data, checked against Daikin, Honeywell and Chemours charts
Diagnostics
AC Temperature Split Calculator
Expected cooling split from SHR and CFM per ton, or delivered BTU/h and SHR from your readings.
Delivered mode uses return and supply dry-bulb and wet-bulb with the ASHRAE enthalpy equations. Cooling only, no charge diagnosis, no model ratings.
Based on ASHRAE Fundamentals psychrometrics
Refrigerant charge
Line Set Charge Calculator
Ounces to add past the factory line length, from the rate in your installation instructions.
Reference liquid per foot from ACR tube ID and CoolProp density. No line sizing and no A2L charge limit.
Based on Manufacturer's rate, Goodman TP-107M example
Diagnostics
Furnace Temperature Rise Calculator
Rise from supply and return readings against the rating plate range, the CFM that rise implies, or the rise at a given CFM.
Enter the return and supply temperatures and the rise range from the rating plate for a verdict, and the furnace output (or input and AFUE) for an airflow estimate. Or enter the output and CFM for the expected rise. Elevation is corrected with the ASHRAE standard atmosphere. Gas furnaces only; the output is not derated for altitude.
Based on Furnace manufacturers' instructions, ASHRAE Fundamentals Ch. 1 (1.08)
Other calculators
Every calculator here lists the standard it works from and what it leaves out. The numbers are for sales-phase sizing and field checks, not a permit submittal. Methodology lists the standard behind each one.