A first-pass size for estimating and quoting. It does not design the system: no NEC 690, inverter, roof, shading, battery or net metering. A licensed installer designs and permits the system with the local authority having jurisdiction and the utility.

Maintained by BuildSolver · Updated

Calculator · Electrical

Solar panel system size calculator

The panel kilowatts a house needs are its yearly kWh divided by 365 times the peak sun hours times what is left after losses. The average U.S. home used 10,791 kWh in 2022. At Phoenix's 6.5 peak sun hours and the default 23 percent total losses that is 5.91 kW DC, or 15 panels of 400 W; at Seattle's 3.7 it is 10.38 kW DC. This page sizes the panels only. For the wire from the inverter, take the current to the wire size calculator.

  1. Choose yearly or monthly kWh and enter the figure from the utility bills. A year of bills is better than one month.
  2. Choose the nearest city of similar climate for its peak sun hours, or pick Other and enter the peak sun hours from PVWatts.
  3. Leave total losses at 23 percent, the PVWatts V1 derate, or raise it for a shaded roof. Enter the watts on the panel label.

DC panel kilowatts and the panel count from yearly or monthly kWh. Peak sun hours are for south-facing panels at the latitude tilt; losses are your entry. No NEC 690, inverter, battery, net metering or payback.

A year of bills gives the best figure. A single month is multiplied by 12, which hides the summer and winter swing.

The kWh the panels should cover, from the utility bill. The U.S. average home used 10,791 kWh in 2022, about 899 kWh per month.

Peak sun hours from the NREL data manual, south-facing panels tilted at the latitude. Pick the nearest city of similar climate, or enter your own.

Everything between the panels and the AC side: soiling, shading, wiring, mismatch, the inverter and cell temperature. 23 is the old PVWatts V1 derate of 0.77, a middle value; the PVWatts 14 percent alone leaves out the inverter and temperature.

The STC rating on the module label. 400 W is typical of a current residential panel.

Example result for the default inputs

10,791 kWh a year, Phoenix, AZ, tilt at latitude, 23 percent losses, 400 W panels.

Array size

5.91 kW DC

Panels

15 x 400 W

Calculation details
Yearly use10,791 kWh per year
Peak sun hours6.5 kWh/m2/day, Phoenix, AZ, tilt at latitude
Total losses, DC to AC23 percent, so 0.77 of the DC energy reaches the AC side
Array size10,791 kWh / (365 x 6.5 x 0.77) = 5.91 kW DC
Panels5,907 W / 400 W = 14.77, rounded up to 15 panels, 6.00 kW DC installed
Output of those panels6.00 kW x 365 x 6.5 x 0.77 = 10,961 kWh per year, 102 percent of the use
Not in this numberRoof area, tilt and direction, shading beyond the loss entered, inverter and AC sizing, NEC 690 string and conductor design, batteries, net metering and payback. For a permit or an incentive claim, run PVWatts or SAM with the site data.

For estimation purposes only. Consult a licensed engineer for final designs.

Get this result as a PDF, free account

Sign up with your email. Back on this page in the same browser, your inputs are filled in. No card.

How kWh becomes panel kilowatts

A kilowatt of panels makes about one kilowatt-hour for each peak sun hour, less the losses between the panels and the AC side. Peak sun hours are the annual average daily radiation on the panel plane in kWh/m2/day, so a year of production is the panel kilowatts times 365 times the peak sun hours times what is left after losses. The page solves that for the kilowatts, then divides by the panel wattage and rounds up to whole panels.

Array size
kW DC = annual kWh / (365 x PSH x (1 - loss))At Phoenix's 6.5 peak sun hours and 23 percent losses, 1 kW DC makes 1,827 kWh a year, so 10,791 kWh needs 5.91 kW DC. At Seattle's 3.7 it makes 1,040 kWh, and the same house needs 10.38 kW DC.
Monthly use
annual kWh = monthly kWh x 12A flat month. 899 kWh per month at Phoenix gives 10,788 kWh a year and 5.91 kW DC. A single summer or winter bill does not represent the year; use twelve months if you have them.
Peak sun hours
PSH = annual kWh/m2/day, south-facing, tilt = latitudeOne peak sun hour is 1 kWh/m2, the energy of 1 kW/m2 for an hour. NREL's data manual gives 6.5 for Phoenix, 4.4 for Chicago and 3.7 for Seattle. It is the annual average, not the summer peak.
System losses
derate = 1 - loss / 100PVWatts defaults to 14 percent system loss, a derate of 0.86; its ten loss items compound to 14.08 percent, they do not add. PVWatts models the inverter (96 percent) and the cell temperature separately. This page has no hourly model, so one total carries all three, and the default is the PVWatts V1 overall derate of 0.77, 23 percent. Against PVWatts v8 at Phoenix (1,780 kWh per kW per year) it gives 1,827, and at Seattle (1,076) 1,040.
Panels
panels = ceil(kW DC x 1,000 / panel W)5,907 W of array in 400 W panels is 14.77, so 15 panels and 6.00 kW DC installed. The same array in 350 W panels takes 17 and in 450 W panels 14.
Check
kWh per year = kW DC x 365 x PSH x (1 - loss)The 15 panels make 10,961 kWh a year, 102 percent of the 10,791 kWh, because the count rounds up.

One house in eight climates

The same 10,791 kWh a year, 23 percent losses and 400 W panels. Peak sun hours are the NREL data manual values for south-facing panels tilted at the latitude; the array grows from 5.91 kW at Phoenix (6.5) to 10.38 kW at Seattle (3.7).

Array size and panel count for one house in eight cities
CityPeak sun hoursArray, kW DCPanels, 400 W
Phoenix, AZ6.55.9115
Las Vegas, NV6.55.9115
Albuquerque, NM6.46.0015
Miami, FL5.27.3819
Boston, MA4.68.3521
Chicago, IL4.48.7322
Portland, OR3.99.8425
Seattle, WA3.710.3826

The panel count rounds up, so the array makes slightly more than the use. A roof with less room than the count needs gives an offset below 100 percent, not a smaller size.

Standards and data sources

Limitations of this calculator

  • This is a first-pass size for a quote or a sales conversation, not a design or a production guarantee. A licensed installer designs the system from a site survey and the permit and interconnection rules of the local authority having jurisdiction (AHJ) and the utility.
  • It does not size the electrical side. NEC Article 690 (voltage and string limits, rapid shutdown, overcurrent protection, conductors and grounding), the inverter and the AC breaker are not worked here.
  • Peak sun hours are for south-facing panels tilted at the latitude. A roof that faces east or west, a shallow or steep pitch and shade from trees or chimneys cut production below this figure; enter the extra loss in the loss field or use PVWatts with your tilt and azimuth.
  • The city table is 1961-1990 data from a 1994 NREL manual, 15 cities only. PVWatts v8 uses newer weather years and a finer grid, and models the cell temperature hour by hour, so its figure for the same city can differ by a few percent: the 23 percent default sits about 3 percent above it in hot Phoenix, where cell temperature costs more, and close to it in Seattle once the same sunshine data are used. For another place, enter peak sun hours from PVWatts (solrad_annual).
  • The loss entry is one number for everything between the panels and the AC side. If you start from the PVWatts 14 percent, add the inverter (96 percent) and the temperature effect, which together bring it to about 23 percent; do not enter 14 and count the inverter on top again. For a design, run PVWatts or SAM.
  • Monthly use is multiplied by 12. Panels make more in summer and less in winter, and a home's use follows its own pattern, so the yearly total can match while individual months do not.
  • The array covers a use that stays the same. A future heat pump, electric vehicle or addition adds kWh the page does not know about; add it to the yearly use first.
  • Payback, incentives, batteries, net metering and rate design are not calculated. Whether a full offset is allowed or paid for depends on the utility's interconnection and compensation rules.
  • Panel output is taken at its STC nameplate. Panel degradation over the years, about 0.5 percent a year in the PVWatts manual, is not part of the first-year figure beyond the nameplate and light-induced loss items inside the PVWatts loss build-up.

Common mistakes sizing a solar system

  1. Using hours of daylight as peak sun hours. Twelve hours of daylight is not twelve peak sun hours. Peak sun hours are the radiation in kWh/m2 a day, 6.5 at Phoenix. Using 12 for 10,791 kWh gives 3.20 kW DC, against the 5.91 kW the NREL figure gives, an array about half the size it should be.
  2. Typing the monthly figure into the yearly field. 899 kWh is per month. Entered as a year at Phoenix it gives 0.49 kW DC, 2 panels, where the real need is 5.91 kW DC. Pick the period first, then enter the number.
  3. Setting the losses to zero. No losses means every kWh the panels make reaches the house. At Phoenix that sizes the house at 4.55 kW DC; at the default 23 percent it is 5.91 kW, and at 30 percent for a partly shaded roof 6.50 kW. An array sized at zero loss falls short of the use every year.
  4. Entering the PVWatts 14 percent as the total. The PVWatts 14 percent is the system loss only. The inverter and the cell temperature come on top of it. Entered as the total at Phoenix it gives 5.29 kW DC, 0.62 kW less than the 5.91 kW at the default 23 percent, an array that falls short of the use. Enter 14 only if you add the inverter and temperature loss elsewhere.
  5. Rounding the panel count down. 14.77 panels is 15 panels, not 14. 14 panels of 400 W make about 10,230 kWh a year against the 10,791 kWh needed. The roof may not hold the extra panel, in which case the offset is below 100 percent, not the size.
  6. Taking the nearest city for a different climate. Chicago gets 4.4 peak sun hours and Seattle 3.7, so the same 10,791 kWh takes 8.73 kW DC in Chicago and 10.38 kW in Seattle, against 5.91 kW in Phoenix. Pick a city with a similar sky, or enter the peak sun hours for the site from PVWatts.

Common questions about solar system size

How do I calculate the solar system size I need?

Divide the yearly kWh by 365 times the peak sun hours times one minus the losses. For 10,791 kWh at Phoenix's 6.5 peak sun hours and 23 percent losses: 10,791 / (365 x 6.5 x 0.77) = 5.91 kW DC.

How many solar panels do I need?

Divide the array watts by the panel watts and round up. 5.91 kW is 5,907 W, which is 14.77 panels of 400 W, so 15. The same array takes 17 panels of 350 W or 14 of 450 W.

What are peak sun hours?

The annual average daily solar radiation on the panels in kWh/m2/day. One peak sun hour is 1 kWh/m2, the energy of full sun at 1 kW/m2 for one hour. It is not the hours of daylight. NREL's data manual gives 6.5 for Phoenix, 4.6 for Boston and 3.7 for Seattle, for south-facing panels tilted at the latitude.

What is a good system loss percentage?

This page defaults to 23 percent for the whole path from panel to AC. NREL's PVWatts uses 14 percent for the system loss alone, built from soiling, shading, mismatch, wiring, connections, light-induced degradation, nameplate rating and downtime, and the ten items compound to 14.08 percent. The inverter and the cell temperature come on top of that. The old PVWatts V1 derate of 0.77 was a single factor built from its own conservative items; it is used here as a middle value, not as a PVWatts output. Raise the loss for a shaded roof.

How many kWh does 1 kW of solar produce a year?

Peak sun hours x 365 x (1 - loss). At 23 percent losses, 1 kW DC makes about 1,827 kWh a year at Phoenix (6.5 peak sun hours) and 1,040 kWh at Seattle (3.7).

How big a solar system does the average home need?

The average U.S. home used 10,791 kWh in 2022, about 899 kWh per month, according to the EIA. Covering all of it at 23 percent losses takes 5.91 kW DC at Phoenix, 8.73 kW at Chicago and 10.38 kW at Seattle. A home's own use decides the real number.

Should I enter monthly or yearly use?

Yearly, from twelve months of bills, if you have it. A monthly figure is multiplied by 12, so 899 kWh per month is 10,788 kWh a year. A single summer month overstates the year and a winter month understates it.

Does this include the inverter, batteries or the NEC 690 design?

No. The page sizes the DC panels and counts them. The inverter, string layout, rapid shutdown, conductors and overcurrent protection under NEC Article 690 are designed by the installer, and batteries and net metering are not calculated.

Can I size solar for a monthly offset instead of the whole year?

Not directly. The page works on the yearly total. If a utility credits surplus over the year, the yearly size is the one to look at; if it settles every month, the winter month sets the need, and the array is larger than the yearly average gives.

Used on the same job