Worksheet / Manual J · #BS-2026-0001
Design conditions - Houston KIAH
ACCA MJ8 · Table 4A - Sensible envelope loads
Cooling load · ACCA MJ8 § 6.4
For HVAC contractors who quote fast
Built on ACCA Manual J procedures. Sonnet 4.6 orchestrates, deterministic code runs the numbers. Every result cites the table it came from.
Worksheet / Manual J · #BS-2026-0001
Design conditions - Houston KIAH
ACCA MJ8 · Table 4A - Sensible envelope loads
Cooling load · ACCA MJ8 § 6.4
Free · No signup · Daily limit applies
Worksheet legend
01
Project name, address, climate zone, date. Same fields a senior engineer would write on the title block of a hand-drawn Manual J.
02
Every row points at the ACCA table it came from. Tap the orange tag to see the section. No "trust me, the AI knows."
03
BuildSolver is sales-grade. The orange stamp tells your AHJ this is preliminary — for permits, use Wrightsoft.
Calculators
Single-purpose calculators for the numbers that come up on a job, each with the standard it works from. The on-page calculators need no signup.
Tools, not guesses
Claude orchestrates the conversation. A library of deterministic calculators returns the number, the formula, and the citation. The math stays canonical; the AI only routes and explains. Design temperatures, IECC adoption, and licensing context are pre-loaded per state — see Manual J for Florida or Manual J for Arizona for hot-climate examples.
ACCA MJ8
Residential cooling and heating loads with design conditions looked up for the site: ASHRAE 2021 station values when the site is one of 10 metro cities; an approximate IECC climate zone estimate for a ZIP code or any other location. Sensible / latent split per Manual J §6.
ACCA MS
Air conditioners, heat pumps, furnaces, dual-fuel. Sensible / latent gating, balance point, aux heat. Manual S first-edition limits.
ACCA MD
Trunk and branch sizing, friction-rate selection, total external static pressure check. Simplified for sales-phase quotes.
ASHRAE Fund
Wet/dry bulb, dew point, humidity ratio, enthalpy. Refrigerant-cycle and IAQ inputs from a single state-point call.
Behind the worksheet
BuildSolver asks the same clarifying questions a senior engineer would. Three messages from a sentence to a citation-ready load. The Houston example below uses the ASHRAE 2021 1% cooling design temperatures for Houston; Manual J for Texas lists the 0.4% values.
BuildSolver
Any envelope upgrades since construction — attic insulation topped up, air-sealing? On a house this age it moves the number half a ton.BuildSolver · 14 sec
Total cooling load: 21,100 BTU/hr (≈ 2 ton). Sensible 18,540 / latent 2,530. Per ACCA Manual J § 6.4 — full breakdown in the worksheet above.
Open in chat →Speed delta
For permit submissions Wrightsoft is the right answer. For sales calls and client quotes, the math is the same and 30 minutes is too long.
| Step | Excel + Word | BuildSolver |
|---|---|---|
| Setup time | 30–45 min | 90 sec |
| Climate-zone lookup | Look up by hand | Auto from address |
| Citation of ACCA tables | If you remember | Auto |
| Mobile on the truck | Painful | First-class |
| Branded client PDF | Build in Word | One click |
| Permit-grade Manual J | No | No — use Wrightsoft |
Common use cases
Four guides covering the most common HVAC sizing scenarios. Each one walks through a concrete project example, comparison with the alternative tool, and FAQs.
Retrofit
For replacement and upgrade jobs that never had original drawings. Describe what you see on site; get the Manual J.
Read →
Replacement
Same Manual J procedures as Carrier HAP, without the brand lock. Mobile-first.
Read →
New construction
Numbers for framing decisions before drawings are stamped. Iterate as the spec firms up.
Read →
Permit
Honest guide to the line between sales-phase sizing and permit-grade Manual J.
Read →
Manual J by state
State-specific Manual J pages with top-metro design temperatures, IECC adoption, and HVAC contractor licensing context already applied to the defaults.
Guides & tools
Written for contractors who have to defend the sizing to a client or an inspector — worked examples, where the rules of thumb break, and which ACCA calculation decides what.
14 min read
An AC-250 meter is rated 250 cfh at a 0.5 in. w.c. drop, and a 24 kW Generac Guardian burns 306 cfh at full load. Add up the house in cfh before you call.
13 min read
Lennox lists 336 psig liquid and 133 psig suction for its 3-ton EL16KC1-036 (R-454B, TXV) at 95°F outdoor. Read any gauge set against outdoor temperature.
15 min read
IMC 307.2.4 leaves the trap to the manufacturer. Goodman's AMST manual asks for a 2 in. drop and a 2.75 in. seal. Check it against the static at the pan.
9 min read
Heat loss / design dT x 24 x HDD / AFUE / 100,000 gives therms. A 40,000 Btu/h Atlanta house comes to about 568 a year at 95% AFUE on a 65°F base, 296 at 57°F.
Straight answers
Describe the building. Get an ACCA-cited load and a branded client PDF. Free to try — no signup.
Open BuildSolver →