Maintained by BuildSolver · Updated
Calculator · Construction
Rebar calculator
Enter the sides of a slab or the length of a footing, the bar spacing and size, the stock bar length, the lap and a waste allowance, and this page gives the bars in each direction, the stock bars to order and the weight of the steel. A 20 x 20 ft slab at 12 in has 21 bars each way, 42 runs and 840.0 ft of bar; the default 30 x 24 ft slab is 84 bars of 20 ft and 1,113.4 lb of #4 with laps and 5 percent waste. For the concrete use the concrete calculator; for a poured ramp, the wheelchair ramp length calculator.
- The sides of the slab in feet, or the footing length and the number of long bars, with the bar size, the spacing in inches and the lap. This page does not choose them; the drawings and the structural engineer do.
- The length of the bars you buy, 20 ft as a default, the lap in bar diameters or in inches, and a waste allowance for cutting loss and spares.
- The result gives the stock bars to order, the bar length with laps and waste, the weight in pounds, and the weight of the layout alone, with a second count if every run is cut from new bars.
- The notes list the last bar's gap to the far edge where the side is not a whole number of spacings, the offcut assumption and what the page does not count.
Example result for the default inputs
Slab 30 x 24 ft, #4 at 12 in each way, 20 ft bars, lap 40 diameters x 0.500 in = 20.0 in, 5 percent waste.
Stock bars
84 x 20 ft
Bar length with laps and waste
1,666.7 ft
Weight with laps and waste
1,113.4 lb
Weight of the layout alone
998.0 lb
| Layout | Slab mat, bars in both directions |
|---|---|
| Bar | #4: 0.500 in nominal diameter (4/8 in), 0.668 lb/ft (ASTM A615 nominal mass) |
| Bars each way | Across the 24 ft width: floor(24 x 12 / 12) + 1 = 25 bars of 30 ft. Across the 30 ft length: floor(30 x 12 / 12) + 1 = 31 bars of 24 ft |
| Layout length | 56 runs, 1,494.0 ft in all, 998.0 lb at 0.668 lb/ft |
| Lap | 40 diameters x 0.500 in = 20.0 in, your value; this page does not check it against the code |
| Pieces per run | bars parallel to the length: 30.0 ft run = 2 pieces, 31.7 ft of bar with laps; bars parallel to the width: 24.0 ft run = 2 pieces, 25.7 ft of bar with laps |
| Bar length with laps | 1,587.3 ft; with 5 percent waste 1,666.7 ft |
| Stock bars, offcuts reused | ceil(1,666.7 / 20) = 84 |
| Stock bars, no offcuts reused | 112, if every run is cut from new bars (waste not added on top) |
| Weight | 1,666.7 ft x 0.668 lb/ft = 1,113.4 lb, or 0.557 short tons |
- Offcuts reused, 84 bars cover it; if each run is cut from new bars and the offcuts are scrapped, it takes 112. Cut and splice the runs so the offcuts go into the next run, or order toward the larger number.
- The lap, the spacing, the bar size and the cover are your inputs. This page counts and weighs material only; it does not size the reinforcement or check a lap length, and a structural engineer or the drawings set those. Cover is taken off by typing the smaller run.
- Weights are the nominal ASTM A615 masses per foot. Delivered bars vary within the mill tolerance, and the tag weight of a bundle can differ. Hooks, bends, chairs, tie wire and spacers are not counted.
For estimation purposes only. Consult a licensed engineer for final designs.
Sign up with your email. Back on this page in the same browser, your inputs are filled in. No card.
Free without signup
How the bars and the weight are found
The page counts the bars in the layout you describe, adds the laps where a run is longer than one stock bar, adds the waste allowance, and converts the length to stock bars and to weight with the ASTM A615 nominal mass of the bar size. It does not choose the bar size, the spacing or the lap: those come from the drawings.
- Bars in one direction
bars = floor(side x 12 / spacing) + 1A side of 20 ft at 12 in is 20 spacings and 21 bars, one more than the spacings because both edges carry a bar. On a slab of 30 x 24 ft at 12 in there are 25 bars of 30 ft across its width and 31 bars of 24 ft across its length. When a side is not a whole number of spacings, the last bar stops short of the far edge, and the page says by how much.- Pieces in one run
pieces = 1 if run <= stock, else 1 + ceil((run - stock) / (stock - lap))A 30 ft run from 20 ft bars is 360 in against 240 in of stock; with a 20 in lap each extra piece adds 220 in, so 1 + ceil(120 / 220) = 2 pieces. At 24 ft a run is also 2 pieces. Exactly 20 ft is one bar.- Bar length of one run
length = run + (pieces - 1) x lapThe 30 ft run needs 31.7 ft of bar, 360 in plus one 20 in lap. The lap is your input, in diameters or in inches; a 40 diameter lap of #4 is 40 x 0.500 = 20 in.- Order length with waste
order length = sum of run lengths x (1 + waste / 100)Runs plus laps total 1,587.3 ft; with 5 percent waste 1,666.7 ft. Without laps and waste the layout alone is 1,494.0 ft.- Stock bars
stock bars = ceil(order length / stock length)1,666.7 / 20 = 83.3, rounded up to 84. This counts the offcuts as used. If every run is cut from new bars the count is the sum of the pieces of all runs, 112 here, and the page shows both.- Weight
weight = order length x nominal mass per foot1,666.7 ft x 0.668 lb/ft = 1,113.4 lb for #4. The nominal masses of ASTM A615 are 0.376 (#3), 0.668 (#4), 1.043 (#5), 1.502 (#6), 2.044 (#7) and 2.670 (#8) lb/ft; one 20 ft #4 bar is 13.36 lb.- Cross ties on a footing
ties = floor(length x 12 / spacing) + 1, ties per bar = floor(stock x 12 / cut length)A 60 ft footing with ties at 12 in has 61 ties. At a cut length of 60 in a 20 ft bar gives 4 ties, and with 5 percent waste 65 ties take 17 bars. The cut length is the number the drawings give.
Six slabs of #4 at 12 in
Each row is a slab mat of #4 bars, 20 ft stock, a lap of 40 bar diameters (20 in) and 5 percent waste, worked with the same function as the form. A 10 x 10 ft slab takes 12 bars and 154.3 lb, and a 40 x 40 ft slab takes 187 bars and 2,492.3 lb. The last column is the count if every run is cut from new bars.
| Slab | Bars | Runs | Length with waste, ft | Stock bars | No offcut reuse | Weight, lb |
|---|---|---|---|---|---|---|
| 10 x 10 ft | #4 at 12 in | 22 | 231.0 | 12 | 22 | 154.3 |
| 20 x 20 ft | #4 at 12 in | 42 | 882.0 | 45 | 42 | 589.2 |
| 30 x 24 ft | #4 at 12 in | 56 | 1,666.7 | 84 | 112 | 1,113.4 |
| 20 x 20 ft | #4 at 18 in | 28 | 588.0 | 30 | 28 | 392.8 |
| 40 x 30 ft | #4 at 12 in | 72 | 2,773.8 | 139 | 175 | 1,852.9 |
| 40 x 40 ft | #4 at 12 in | 82 | 3,731.0 | 187 | 246 | 2,492.3 |
Offcuts account for the gap between the two bar counts: a 30 ft or 40 ft run from 20 ft bars leaves a piece, and whether the crew uses it decides which count is nearer the order. Bar weights per foot are the nominal ASTM A615 masses, 0.376 lb/ft for #3 up to 2.670 lb/ft for #8.
Standards and data sources
- Caltrans, Bridge Design Details, Chapter 13 Reinforcement, Table 13.1.1 ASTM Standard Reinforcing Bar Data (September 2025) - The source of the nominal masses per foot used here, read in the PDF: #3 0.376, #4 0.668, #5 1.043, #6 1.502, #7 2.044 and #8 2.670 lb/ft, with nominal diameters 0.375 to 1.000 in. The table is the state's printing of the ASTM bar sizes; the ASTM standard itself is sold by ASTM and was not read for this page.
- Engineering ToolBox, Rebar - U.S. Imperial Reinforcing Bar - A second open page with the same six weights per foot and the nominal diameters 3/8, 1/2, 5/8, 3/4, 7/8 and 1 in for #3 to #8. It names no standard, so it serves as a cross check on the table above.
Limitations of this calculator
- This page counts and weighs reinforcing steel for a layout you describe. It is a takeoff aid for a quote or an order, not a design. It does not replace the design of a structural engineer: the bar size, spacing, cover, laps and detailing come from the drawings and the building code, and the building department decides.
- The lap is your input, in bar diameters or in inches. The page does not compute a splice or development length from ACI 318 or any other code and does not check that the lap you type is long enough. A rule of thumb you remember is not a substitute for the length the drawings call for.
- The count is floor(side / spacing) + 1 bars in each direction, with the bars running the full side you type. Cover is taken off by typing the smaller side, and a side that is not a whole number of spacings leaves the last bar short of the far edge; add a bar by hand if the drawings ask for one there.
- Pieces per run are counted from the stock length and the lap: the first piece takes its full length and each extra piece adds the stock length less the lap. The headline stock bar count assumes the offcuts are used; the row below it gives the count if every run is cut from new bars. The real figure falls between them and depends on how the crew cuts.
- Weights are the nominal masses per foot of the ASTM bar sizes as Caltrans prints them in Table 13.1.1, cross checked on a second open page, not read in the ASTM standard itself. Delivered bars vary within the mill tolerance, and a bundle's tag weight can differ from the nominal figure. Hooks, bends, bar supports (chairs), tie wire, couplers and spacers are not counted.
- Bar sizes #3 to #8 are supported. Sizes #9 to #18 and the soft-metric designations are not in the table, and neither are epoxy-coated, galvanized, welded wire reinforcement or fiber products, whose masses differ.
- For a footing the long bars run the full length you type, with the same lap and waste. Cross ties are counted from a spacing and a cut length you enter; the page does not work out the cut length from a hook or a footing section, and it does not size the ties or check that their spacing is a structural one.
- Values outside the field ranges are not accepted: slab sides 1 to 500 ft, footing length 1 to 2,000 ft, spacing 2 to 48 in, stock bars 2 to 60 ft, lap 0 to 200, waste 0 to 50 percent, 1 to 30 long bars and a tie cut length of 6 to 200 in. A spacing larger than a side, or a lap that is not shorter than the stock bar, is refused with a sentence. These bounds are this page's own, not a code's.
Common mistakes when counting rebar
- Counting spacings instead of bars. A 20 ft side at 12 in has 20 spacings and 21 bars, since a bar sits on each edge. Taking 20 bars each way gives 40 runs and 800 ft against the 42 runs and 840.0 ft the page counts, a miss of 40.0 ft of bar.
- Leaving the laps out. Where a run is longer than one stock bar the bars overlap. The 30 x 24 ft slab is 1,494.0 ft of runs, and with a 40 diameter lap of #4 (20 in) at every splice it is 1,587.3 ft before waste. A 60 in lap makes it 1,774.0 ft, so the lap you take from the drawings moves the order.
- Misreading the bar number. The number is the nominal diameter in eighths of an inch: #4 is 1/2 in, #8 is 1 in. Weight grows with the square of the diameter. The same 20 x 20 ft mat at 12 in is 589.2 lb in #4, 919.9 lb in #5 and 2,354.9 lb in #8, and 331.6 lb in #3. Check the number on the drawings before you price it.
- Counting stock bars from length alone. The 30 x 24 ft slab needs 1,666.7 ft of bar, which is 84 bars of 20 ft only if the offcuts are used. Each of its runs is 24 ft or 30 ft, so each takes two bars, and cutting every run from new bars takes 112. Plan the cuts, and order toward the larger number when offcuts cannot be reused.
- Typing the spacing in feet. The spacing is in inches, center to center, and the sides are in feet. Typing 1 for a spacing of 1 ft gives 1 in, which the page refuses because it is under 2 in. Typing 2 for 2 ft is accepted as 2 in and counts 121 bars each way on a 20 ft side, against 21 at 12 in. Check the unit on the field.
- Forgetting the waste allowance. The 30 x 24 ft slab is 1,060.3 lb with no waste and 1,113.4 lb with 5 percent, and 80 bars against 84. Cutting loss and spares are real; add an allowance from your own jobs or your supplier and keep it as a line the client can see.
Common questions about rebar
How many rebar bars does a 20 x 20 ft slab need at 12 in spacing?
Each direction has floor(240 / 12) + 1 = 21 bars, so the mat is 42 bars of 20 ft, 840.0 ft of bar. A 20 ft bar fits each run, so there are no splices. With 5 percent waste that is 882.0 ft, 45 bars of 20 ft, and 589.2 lb in #4.
How much does rebar weigh per foot?
The nominal masses of ASTM A615 bars are 0.376 lb/ft for #3, 0.668 for #4, 1.043 for #5, 1.502 for #6, 2.044 for #7 and 2.670 for #8. A 20 ft bar of #4 is 13.36 lb and of #5 is 20.86 lb. The bar number is the diameter in eighths of an inch, so #4 is 1/2 in. Delivered bars vary a little within the mill tolerance.
How is the number of bars in a grid counted?
For each direction take the side in inches, divide by the spacing, round down and add one. A 20 ft side is 240 in: at 12 in spacing that is 21 bars, at 16 in 16, at 18 in 14 and at 24 in 11. Where the side is not a whole number of spacings the last bar sits short of the far edge: at 18 in, 6 in short.
How many 20 ft bars do I need for a slab?
Add up the length of every run, add the laps where a run is longer than 20 ft, add waste, and divide by 20, rounding up. A 30 x 24 ft slab at 12 in is 1,494.0 ft of runs, 1,587.3 ft with a 20 in lap at each splice, 1,666.7 ft with 5 percent waste: 84 bars if offcuts are reused, up to 112 if each run is cut from new bars.
How long is a rebar lap?
The lap is the length the project calls for, and this page takes it as your input, in bar diameters or in inches. It does not compute it: splice and development lengths are set by the structural design and the code, for example ACI 318, and depend on bar size, concrete strength and position. For the page example a lap of 40 diameters of #4 is 20 in, and each splice adds that much bar. With no lap the 30 x 24 slab is 1,494.0 ft; with the 20 in lap it is 1,587.3 ft.
How much rebar does a strip footing need?
Count the long bars along the footing and any cross ties. A 60 ft footing with 4 long bars of #4 is 240 ft of bar; a 60 ft run from 20 ft bars is 4 pieces with 3 laps of 20 in, so 260.0 ft with laps and 273.0 ft with 5 percent waste: 14 bars, 182.4 lb. With #3 ties at 12 in and a 60 in cut length add 61 ties, 17 bars and 122.2 lb, 304.6 lb in all.
How much waste should I add for rebar?
This page found no code or standard figure for the allowance, so it is your own, from your own jobs or your supplier. The page accepts 0 to 50 percent and the default of 5 is its own pick. On the 30 x 24 ft slab, 5 percent moves the weight from 1,060.3 lb to 1,113.4 lb. Whether offcuts can be used again matters as much as the percentage.
Does this calculator size the rebar?
No. It counts and weighs the bars of a layout you describe. The bar size, the spacing, the cover and the lap come from the project drawings and the building code, and a structural engineer designs them. The page is for takeoff, quoting and ordering.